E6581160
QTable of input terminal functions 2
|
| Function | Code | Function | Action | |
|
| No. | ||||
|
|
|
|
| ||
|
| 34 | F+SS3+AD2 | Combination of forward run, | ON: Simultaneous input from F, SS3 and AD2 | |
|
|
|
| command 3 and acceleration/deceleration 2 |
| |
|
| 35 | R+SS3+AD2 | Combination of reverse run, | ON: Simultaneous input from R, SS3 and AD2 | |
|
|
|
| command 3 and acceleration/deceleration 2 |
| |
|
| 36 | F+SS4+AD2 | Combination of forward run, | ON: Simultaneous input from F, SS4 and AD2 | |
|
|
|
| command 4 and acceleration/deceleration 2 |
| |
|
| 37 | R+SS4+AD2 | Combination of reverse run, | ON: Simultaneous input from R, SS4 and AD2 | |
|
|
|
| command 4 and acceleration/deceleration 2 |
| |
|
| 38 | FCHG | Frequency command forced switching | ON: H(If H = ) | |
|
|
|
|
| OFF: HOQF | |
|
| 39 | VF2 | No.2 Switching of V/F setting | ON: No.2 V/F setting | |
|
|
|
|
| (RV=0, H, H, H, H) | |
|
|
|
|
| OFF: No.1 V/F setting | |
|
|
|
|
| (Set value of RV, XN, XNX, XD, VJT) | |
|
| 40 | MOT2 | No.2 motor switching | ON: No.2 motor | |
|
|
|
| (VF2+AD2+OCS2) | (RV=0, H, H, H, H, | |
|
|
|
|
| H, H, H, H) | |
|
|
|
|
| OFF: No.1 motor (Set value of RV, XN, XNX, | |
|
|
|
|
| XD, VJT, CEE, FGE, H, H) | |
|
| 41 | UP | Frequency UP signal input from external contacts | ON: Increase in frequency | |
|
| 42 | DOWN | Frequency DOWN signal input from external | ON: Reduction in frequency | |
|
|
|
| contacts |
| |
|
| 43 | CLR | Frequency UP/DOWN cancellation signal input | OFF→ON: Resetting of UP/DOWN frequency by | |
|
|
|
| from external contacts | means of external contacts | |
|
| 44 | CLR+RES | Combination of frequency UP/DOWN cancellation | ON: Simultaneous input from CLR and RES | |
7 | ||||||
|
|
| and reset by means of external contacts |
| ||
| 45 | EXTN | Inversion of trip stop command from external | OFF: G Trip stop | ||
|
|
| device |
| ||
|
| 46 | OH | Thermal trip stop signal input from external device | ON: QJ Trip stop | |
|
| 47 | OHN | Inversion of thermal trip stop command from | OFF: QJ Trip stop | |
|
|
|
| external device |
| |
|
| 48 | SC/LC | Forced switching from remote to local control | Enabled when remote control is exercised | |
|
|
|
|
| ON: Local control (setting of cmod, HOQF and | |
|
|
|
|
| H) | |
|
|
|
|
| OFF: Remote control | |
|
| 49 | HD | Operation holding (stop of | ON: F (forward run)/R: (reverse run) held, | |
|
|
|
|
| operation | |
|
|
|
|
| OFF: Slowdown stop | |
|
| 50 | CMTP | Forced switching of command mode and terminal | ON: Terminal board operation | |
|
|
|
| board command | OFF: Setting of EOQF | |
|
| 51 | CKWH | Display cancellation of the cumulative power | ON: Monitor display cancellation of the cumulative | |
|
|
|
| amount (kWh) | power amount (kWh) | |
|
| 52 | FORCE | Forced operation (factory configuration required) | ON: Forced operation mode in which operation is | |
|
|
|
|
| not stopped in the event of the occurrence of | |
|
|
|
|
| a soft fault (preset speed operation frequency | |
|
|
|
|
| 15) To use this function, the inverter needs to | |
|
|
|
|
| be so configured at the factory. | |
|
|
|
|
| OFF: Normal operation | |
|
| 53 | FIRE | ON: | ||
|
|
|
|
| frequency 15) | |
|
|
|
|
| OFF: Normal operation |