Section lX: FBRM/BFFG Cable & Fiber Optic Specifications Transition Networks
Fiber optic cable and connector specifications, continued
Copper-to-fiber connectors with DMI (continued)
Fiber Optics Specifications
1310 nm (TX)/1550 nm (RX) simplex
CFBRM1029-110 DMI 1550 nm (TX)/1310 nm (RX) simplex
CFBRM1029-111 DMI 1310 nm (TX)/1550 nm (RX) simplex
SFBRM1029-110 DMI 1550 nm (TX)/1310 nm (RX) simplex
SFBRM1029-111 DMI min: -14.0 dBm max: -8.0 dBm
Fiber-optic transmitter power: min: -33.0 dBm max: -3.0 dBm
Fiber-optic receiver sensitivity: 19 dB
Link budget:
1310 nm (TX)/1550 nm (RX) simplex
CFBRM1029-112 DMI 1550 nm (TX)/1310 nm (RX) simplex
CFBRM1029-113 DMI 1310 nm (TX)/1550 nm (RX) simplex
SFBRM1029-112 DMI 1550 nm (TX)/1310 nm (RX) simplex
SFBRM1029-113 DMI min: -8.0 dBm max: -3.0 dBm
Fiber-optic transmitter power: min: -33.0 dBm max: -3.0 dBm
Fiber-optic receiver sensitivity: 25 dB
Link budget:
Note: The fiber optic transmitters on these Devices meet Cl ass I Laser safety
requirements per IEC-825/CDRH standards and comply with 21
CFR1040.10 and 21CFR1040.11.
WARNING: Visible and invisible laser radiation when open. Do not stare into the
beam or view the beam directly with optical instruments. Failure to observe this
warning could result in an eye injury or blindness.
WARNING: Use of controls, adjustments or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.
Continued on next page
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 93