Section Vlll: FBRM/BFFG Troubleshooting Transition Networks
Troubleshooting problem and corrective action table, continued
Problem Corrective Action
The Trap Server does not
record traps,(continued) The response is:
FLASH: Saving configuration, please wait up to one minute...
Writing Flash
(04004500,05E8,00FE0000,00FFFFFE)
Erasing
.
Done Erasing/Verifying
Writing [000005E8]
#[0000FFFF]
Done Writing
Verifying
FLASH: Write complete.
Cannot activate IP-based
management
Are the IP, Gateway, and subnet mask configured correctly?
With DHCP enabled, DHCP could have failed leaving the system with
the old static IP config. Verify the configuration via the USB port.
Make sure IP-based access is not turned OFF in the system.
Contact Technical Support. US/Canada: 1-800-260-1312, International:
00-1-952-941-7600.
TLPT and SLDP are not
working
Are the TLPT and SLDP enabled on both systems? Refresh web pages
to make sure they are set.
Check if port binding for TLPT/RFD is set to the active OAM channel.
With 100Base-Fx, make sure “far end fault” is enabled.
Contact Technical Support. US/Canada: 1-800-260-1312, International:
00-1-952-941-7600.
OAM session is not
active If OAM is enabled, check the ports on the local and remote Devices.
Make sure the local Device is in OAM “Active” Mode.
OAM remote Device is
detected on local, but
cannot configure remote
from local
Make sure the remote peer Device is set to “Passive” Mode.
Note: OAM session can be formed between Devices with both set to
Active Mode, but this prevents remote management. The remote
Device should be in “Passive” Mode for management.
Contact Technical Support. US/Canada: 1-800-260-1312, International:
00-1-952-941-7600.
Continued on next page