Section ll: FBRM/BFFG Hardware Installation Transition Networks
Installing CFBRM/CBFFG Devices into point system chassis IMPORTANT The CFBRM/CBFFG Device product family IS NOT compatible with the CPSMM-
200 and CPSMM-210 MGMT modules when used in a cascaded application. The
CFBRM/CBFFG can be installed in the “master” chassis with the CPSMM-200
MGMT module, but they can not be installed in a cascaded chassis using the
CPSMM-210 MGMT module.
Alternatively, the CFBRM/CBFFG can be used with the CPSMM120 MGMT
module, which does not support chassis cascading.
Caution Wear a grounding strap and observe electrostatic discharge precautions when
installing the CFBRM/CBFFG Device into the Point System chassis. Failure
to observe this caution could result in damage to the Device.
Chassis Device
installation To install the chassis Device into the Point System chassis, do the following:
Step Action
1. Locate an empty slot in the Point System chassis.
2. Grasp the edges of the Device by its front panel.
3. Align the Device with the slot guides and carefully insert the Device into
the installation slot.
4. Firmly seat the Device against the chassis back panel.
5. Push IN and ROTATE clockwise the panel-fastener screw to secure the
Device to the chassis. See Figure 12.
Figure 12: CFBRM/CBFFG Device Chassis Installation
18