Transition Networks Section lX: FBRM/BFFG Cable & Fiber Optic Specifications
Fiber optic cable and connector specifications, continued
BFFG fiber-to-fiber Gbit connector (continued)
Fiber Optics Port 1 Specification Port 2 Specification
CBFFG1335-100 1310 nm single mode
1300 nm multimode
SBFFG1335-100 min: 0.0 dBm max: 5.0 dBm
min: -19.0 dBm max: -14.0 dBm
Fiber-optic transmitter power: min: -27.0 dBm max: -3.0 dBm
min: -30.0 dBm max: -14.0 dBm
Fiber-optic receiver sensitivity: 27 dB
11 dB
Link budget:
BFFG fiber-to-fiber Gbit with DMI connector
Fiber Optics Port 1 Specification Port 2 Specification
CBFFG1313-110 DMI 1310 nm single mode
1300 nm multimode
SBFFG1313-110 DMI min: -9.5 dBm max: -4.0 dBm
min: -19.0 dBm max: -14.0 dBm
Fiber-optic transmitter power: min: -18.0 dBm max: -3.0 dBm
min: -30.0 dBm max: -14.0 dBm
Fiber-optic receiver sensitivity: 8.5 dB
11 dB
Link budget:
CBFFG1314-110 DMI
SBFFG1314-110 DMI 1300 nm multimode 1310 nm single mode
Fiber-optic transmitter power: min: -19.0 dBm max: -14.0 dBm min: -9 dBm max: -3.0 dBm
Fiber-optic receiver sensitivity: min: -30.0 dBm max: -14.0 dBm min: -21.0 dBm max: -3.0 dBm
Link budget: 11 dB 12 dB
CBFFG1315-110 DMI 1310 nm single mode
1300 nm multimode
SBFFG1315-110 DMI min: -5 dBm max: 0 dBm
min: -19.0 dBm max: -14.0 dBm
Fiber-optic transmitter power: min: -24.0 dBm max: -3.0 dBm
min: -30.0 dBm max: -14.0 dBm
Fiber-optic receiver sensitivity: 19 dB
11 dB
Link budget:
1310 nm (TX)/1490 nm (RX)
CBFFG1329-110 DMI 1490 nm (TX)/1310 nm (RX)
CBFFG1329-111 DMI 1310 nm (TX)/1490 nm (RX)
SBFFG1329-110 DMI 1490 nm (TX)/1310 nm (RX)
1300 nm multimode
SBFFG1329-111 DMI min: -9.0 dBm max: 3.0 dBm
min: -19.0 dBm max: -14.0 dBm
Fiber-optic transmitter power: min: -20.0 dBm max: -3.0 dBm
min: -30.0 dBm max: -14.0 dBm
Fiber-optic receiver sensitivity: 11 dB
11 dB
Link budget:
Note: The fiber optic transmitters on these Devices meet Cl ass I Laser safety
requirements per IEC-825/CDRH standards and comply with 21
CFR1040.10 and 21CFR1040.11.
WARNING: Visible and invisible laser radiation when open. Do not stare into the
beam or view the beam directly with optical instruments. Failure to observe this
warning could result in an eye injury or blindness.
WARNING: Use of controls, adjustments or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.
Continued on next page
98 24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600