External Controls

01 POWER ON

Function

The external control equipment switches on the power of the plasma monitor.

Transmission Data

9FH

80H

60H

4EH

00H

CKS

 

 

 

 

 

 

ACK

The plasma monitor returns the following ACK when the power is switched on.

3FH

60H

80H

4EH

00H

CKS

 

 

 

 

 

 

NOTE: Do not set the Power ON or Power OFF command continuously.

02 POWER OFF

Function

The external control equipment switches off the power of the plasma monitor.

Transmission Data

9FH

80H

60H

4FH

00H

CKS

 

 

 

 

 

 

ACK

The plasma monitor returns the following ACK when the power is switched on.

3FH

60H

80H

4FH

00H

CKS

 

 

 

 

 

 

NOTE: Do not set the Power ON or Power OFF command continuously.

03 INPUT SWITCH CHANGE

Function

The external control equipment switches the input of the plasma monitor.

Transmission Data

DFH

80H

60H

47H

01H

DATA00

CKS

 

 

 

 

 

 

 

DATA00:

Input Select

 

 

01H: Video1

 

 

 

 

 

 

02H: Video2

 

 

 

 

 

 

03H: Video3

 

05H: HD (HD1 or DTV or DTV1)

06H: HD2 (DTV2)

07H: RGB1/PC1

08H: RGB2/PC2

0CH: RGB3/PC3

ACK

The plasma monitor returns the following ACK when the input is switched.

3FH

60H

80H

47H

00H

CKS

 

 

 

 

 

 

82

Page 83
Image 83