Vidikron VP-50, VP-60, VP-42HD owner manual Inverse Set, Image Sweep Set, External Controls, Standby

Models: VP-42 VP-50 VP-42HD VP-60

1 117
Download 117 pages 32.87 Kb
Page 98
Image 98
35 INVERSE SET

35 INVERSE SET

Function

The external control equipment sets the INVERSE (inverse of image brightness) and the WHITE of the plasma monitor.

Transmission Data

DFH

80H

60H

C7H

03H

DATA00

DATA01

DATA02

CKS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA00:

INVERSE/WHITE

 

 

 

 

 

00H: No operation

 

 

 

 

 

 

 

 

 

 

 

01H: ON (INVERSE)

 

 

 

 

 

 

 

 

 

 

 

02H: OFF

 

 

 

 

 

 

 

 

 

 

 

03H: WHITE

DATA01:

ACTIVE

 

 

 

 

 

 

 

00H: ON

 

 

 

 

 

 

 

 

 

 

 

01H: 03M (minutes)

 

 

 

 

 

 

 

 

 

 

 

02H: 06M (minutes)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FFH: 12H (hours) and 45M

 

 

 

 

 

 

 

 

 

 

 

(minutes)

DATA02:

STANDBY

 

 

 

 

 

 

 

01H: 03M (minutes)

 

 

 

 

 

 

 

 

 

 

 

02H: 06M (minutes)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FFH: 12H (hours) and 45M

 

 

 

 

 

 

 

 

 

 

 

(minutes)

ACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3FH

 

60H

 

80H

 

C7H

 

00H

 

CKS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: The ACTIVE and the STANDBY can be set in units of 3 minutes.

Example: 03H=9 minutes

1EH=1 hour and 30 minutes

External Controls

36 IMAGE SWEEP SET

Function

The external control equipment sets the IMAGE SWEEP of the plasma monitor.

Transmission Data

DFH

80H

 

60H

C8H

04H

DATA00 to DATA03

CKS

 

 

 

 

 

 

 

DATA00:

IMAGE SWEEP

 

 

00H: No operation

 

 

 

 

 

 

01H: ON

 

 

 

 

 

 

02H: OFF

DATA01:

ACTIVE

 

 

 

00H: ON

 

 

 

 

 

 

01H: 03M (minutes)

 

 

 

 

 

 

02H: 06M (minutes)

 

 

 

 

 

 

 

 

 

 

 

 

 

FFH: 12H (hours) and 45M

 

 

 

 

 

 

(minutes)

DATA02:

STANDBY

 

 

 

01H: 03M (minutes)

 

 

 

 

 

 

02H: 06M (minutes)

 

 

 

 

 

 

 

 

 

 

 

 

 

FFH: 12H (hours) and 45M

 

 

 

 

 

 

(minutes)

DATA03:

SPEED

 

 

 

01H: 1

 

 

 

 

 

 

 

 

 

 

 

 

 

05H: 5

ACK

3FH

60H

80H

C8H

00H

CKS

 

 

 

 

 

 

Note: The ACTIVE and the STANDBY can be set in units of 3 minutes.

Example: 03H=9 minutes

1EH=1 hour and 30 minutes

97

Page 98
Image 98
Vidikron VP-50, VP-60, VP-42HD owner manual Inverse Set, Image Sweep Set, External Controls, Standby