43 VIDEO STANDARD SELECT

Function

The external control equipment sets the VIDEO STANDARD of the plasma monitor.

Transmission Data

DFH

80H

60H

5CH

01H

DATA00

CKS

 

 

 

 

 

 

 

DATA00:

01H: 3.58NTSC

 

 

 

 

 

02H: 4.43NTSC

 

 

 

 

 

03H: PAL

 

 

 

 

 

 

04H: SECAM

 

 

 

 

 

05H: AUTO1

 

 

 

 

 

0BH: PAL60

 

 

 

 

 

0CH: AUTO2

 

 

 

 

 

0DH: PAL-M

 

 

 

 

 

0EH: PAL-N

 

 

 

 

ACK

 

 

 

 

 

 

 

 

 

 

 

 

 

7FH

60H

80H

5CH

01H

DATA00

CKS

 

 

 

 

 

 

 

DATA00:

01H: 3.58NTSC

 

 

 

 

 

02H: 4.43NTSC

 

 

 

 

 

03H: PAL

 

 

 

 

 

 

04H: SECAM

 

 

 

 

 

05H: AUTO1

 

 

 

 

0BH: PAL60

0CH: AUTO2

0DH: PAL-M

0EH: PAL-N

External Controls

44 FREQUENCY REQUEST

Function

The external control equipment inquires the Horizontal frequency, Vertical frequency, Horizontal sync polarity, Vertical sync polarity, Mode, and Resolution of the plasma monitor.

Transmission Data

1FH

80H

60H

26H

00H

CKS

 

 

 

 

 

 

ACK

7FH

60H

 

80H

26H

0BH

DATA00 to DATA10

CKS

 

 

 

 

 

 

 

 

Horizontal frequency

 

 

 

 

 

DATA00:

Integer part

 

 

00H: 0 (No signal: 00H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FFH: 256

 

DATA01:

One decimal place

 

 

00H: 0 (No signal: 00H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09H: 9

 

Vertical frequency

 

 

 

 

 

DATA02:

Integer part

 

 

00H: 0 (No signal: 00H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FFH: 256

 

DATA03:

One decimal place

 

 

00H: 0 (No signal: 00H)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

09H: 9

 

Horizontal sync polarity

 

 

 

 

DATA04:

00H: -

 

 

 

 

 

 

01H: Positive

 

 

 

 

 

02H: Negative

 

 

 

 

101

Page 102
Image 102
Vidikron VP-50, VP-60, VP-42HD owner manual Video Standard Select, Frequency Request, 101