04 VOLUME GAIN DATA

04 VOLUME GAIN DATA

Function

The external control equipment changes the VOLUME gain data of the plasma monitor.

Transmission Data

DFH

80H

60H

7FH

03H

DATA00

DATA01

DATA02

CKS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA00:

USER SOUND Gain Flag

 

 

 

 

05H

 

 

DATA01:

VOLUME Gain Flag

 

 

 

 

 

 

01H

 

 

DATA02:

VOLUME Gain

 

 

 

 

 

 

00H: Step 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0AH: Step 10 (Default)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACK

 

 

 

 

 

 

 

 

 

 

2AH: Step 42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7FH

 

60H

 

80H

 

7FH

 

02H

 

DATA00

 

DATA01

 

CKS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA00:

USER SOUND Gain Flag

 

 

 

 

05H

 

 

DATA01:

VOLUME Gain Flag

 

 

 

 

 

 

01H

 

 

05 AUDIO MUTE ON

Function

The external control equipment switches on AUDIO Mute of the plasma monitor.

Transmission Data

9FH

80H

60H

3EH

00H

CKS

 

 

 

 

 

 

ACK

3FH

60H

80H

3EH

00H

CKS

 

 

 

 

 

 

External Controls

06 AUDIO MUTE OFF

Function

The external control equipment switches off AUDIO Mute of the plasma monitor.

Transmission Data

9FH

80H

60H

3FH

00H

CKS

 

 

 

 

 

 

ACK

3FH

60H

80H

3FH

00H

CKS

 

 

 

 

 

 

07 CONTRAST GAIN DATA

Function

The external control equipment changes the CONTRAST gain data of the plasma monitor.

Transmission Data

DFH

80H

60H

7FH

03H

DATA00

DATA01

DATA02

CKS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA00:

USER PICTURE Gain Flag

 

 

 

 

051H

 

 

 

DATA01:

CONTRAST Gain Flag

 

 

 

 

07H

 

 

 

DATA02:

CONTRAST Gain

 

 

 

 

 

 

CCH: -52

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FFH: -01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00H: 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

01H: +01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14H: +20

 

 

 

ACK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7FH

 

60H

 

80H

 

7FH

 

02H

 

DATA00

 

DATA01

 

CKS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA00:

USER PICTURE Gain Flag

 

 

 

 

01H

 

 

 

DATA01:

CONTRAST Gain Flag

 

 

 

 

07H