External Controls

37 FACTORY

Function

The external control equipment resets the user adjustment of the plasma monitor.

Transmission Data

1FH

80H

60H

54H

00H

CKS

 

 

 

 

 

 

ACK

3FH

60H

80H

54H

00H

CKS

 

 

 

 

 

 

38 AUDIO SELECT SET

Function

The external control equipment sets combinations of audio and video inputs for the plasma monitor.

Transmission Data

DFH

80H

60H

70H

02H

DATA00

DATA01

CKS

 

 

 

 

 

 

 

 

DATA00:

AUDIO

 

 

 

 

01H: AUDIO 1

 

 

 

 

 

 

02H: AUDIO 2

 

 

 

 

 

 

03H: AUDIO 3

DATA01:

VISUAL INPUT

 

 

 

01H: Video 1

 

 

 

 

 

 

02H: Video 2

 

 

 

 

 

 

03H: Video 3

 

 

 

 

 

 

05H: HD (HD1 or DVD or DVD1)

 

 

 

 

 

 

06H: HD2 (DTV2)

07H: RGB 1/PC1

08H: RGB 2/PC2

0CH: RGB 3/PC3

ACK

The plasma monitor returns the following ACK when the input is switched.

3FH

60H

80H

70H

00H

CKS

 

 

 

 

 

 

*The plasma monitor returns “Not Available” when selecting the video input same as the one set at one of the AUDIO 1 to 3.

Example:

The plasma monitor returns “Not Available” when selecting the VIDEO1 for AUDIO2 or VIDEO3 after VIDEO1 has been set to AUDIO1.

98

Page 99
Image 99
Vidikron VP-60, VP-42HD, VP-50 owner manual Factory, Audio Select SET