Example 2: Interconnecting a number of camcorders for time code synchronization
| TEST OUT a) |
| TC OUT |
4 | Reference camcorder |
TC IN |
| GENLOCK IN b) |
TC OUT
TEST OUT a)
GENLOCK IN b)
TC IN
TC OUT
TEST OUT a)
To another camcorder to be synchronized
a)When an HKDW-702 (not supplied) is installed, the down-converted video signal of the camcorder cannot be used as the reference signal. When interconnecting a number of camcorders, output the HD analog component signal (HD-Y signal) from the TEST OUT connector.
For details, see “4-8-2 Selecting the Output Signals” on page 4-101.
b)Set GENLOCK to ON on the GENLOCK page of the MAINTENANCE menu.