G-3000H User’s Guide

 

Table 34

VLAN

 

 

 

 

 

 

LABEL

 

DESCRIPTION

 

 

 

 

 

 

 

Name

 

Type a name to have the ZyAIR check for specific VLAN attributes on

 

 

 

 

incoming messages from the RADIUS server. Access-accept packets sent by

 

 

 

 

the RADIUS server contain VLAN related attributes. The configured Name

 

 

 

 

field is checked against these attributes. If the configured Name field matches

 

 

 

 

these attributes, the corresponding VLAN ID entry is used to access the

 

 

 

 

specific VLAN group. If the configured Name field does not match the VLAN

 

 

 

 

related attributes sent from the RADIUS server, a wireless station is assigned

 

 

 

 

the associated SSID VLAN ID. See VLAN ID in the SSID screen.

 

 

Apply

 

Click Apply to save your changes back to the ZyAIR.

 

 

 

 

 

 

 

Reset

 

Click Reset to begin configuring this screen afresh.

 

 

 

 

 

 

9.2.1 Configuring Management VLAN Example

This section shows you how to create a VLAN on an Ethernet switch.

By default, the port on the ZyAIR is a member of the management VLAN (VID 1). The following procedure shows you how to configure a tagged VLAN.

Note: Use the out-of-band management port or console port to configure the switch if you misconfigure the management VLAN and lock yourself out from performing in-band management.

On an Ethernet switch, create a VLAN that has the same management VLAN ID as the ZyAIR. The following figure has the ZyAIR connected to port 2 of the switch and your computer connected to port 1. The management VLAN ID is ten.

Figure 55 Management VLAN Configuration Example

Perform the following steps in the switch web configurator:

1Click VLAN under Advanced Application.2Click Static VLAN.

3Select the ACTIVE check box.

4Type a Name for the VLAN ID.

Chapter 9 VLAN

115