Chapter 21 Troubleshooting

One of the LEDs does not behave as expected.

1Make sure you understand the normal behavior of the LED. See Section 1.7 on page 27.

2Check the hardware connections. See the Quick Start Guide.

3Inspect your cables for damage. Contact the vendor to replace any damaged cables.

4Disconnect and re-connect the power adaptor or PoE power injector to the NWA3000-N series AP.

5If the problem continues, contact the vendor.

21.3NWA3000-N series AP Access and Login

I forgot the IP address for the NWA3000-N series AP.

1The default IP address is 192.168.1.2.

2Use the commands through the console port to check the IP address. Connect your computer to the CONSOLE port using a console cable. Your computer should have a terminal emulation communications program (such as HyperTerminal) set to VT100 terminal emulation, no parity, 8 data bits, 1 stop bit, no flow control and 115200 bps port speed.

3If this does not work, you have to reset the device to its factory defaults. See Section 21.6 on page 277.

I cannot see or access the Login screen in the web configurator.

1Make sure you are using the correct IP address.

The default IP address is 192.168.1.2.

If you changed the IP address, use the new IP address.

268

 

NWA3000-N Series User’s Guide