Texas Instruments TNETX4090 specifications MII management interface

Page 14

TNETX4090

ThunderSWITCH II9-PORT 100-/1000-MBIT/S ETHERNETSWITCH

SPWS044E ± DECEMBER 1997 ± REVISED AUGUST 1999

 

 

 

 

 

 

 

 

 

 

 

Terminal Functions (Continued)

10-/100-Mbit/s MAC interface (MII mode) (ports 0±7) (continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

TERMINAL

 

I/O

 

INTERNAL

 

DESCRIPTION

 

NAME

NO.

 

 

RESISTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M00_TXEN

D22

 

 

 

 

 

 

 

 

 

M01_TXEN

B17

 

 

 

 

 

 

 

 

 

M02_TXEN

B13

 

 

 

 

 

 

 

Transmit enable. Indicates valid transmit data on Mxx_TXDn. This signal is synchronous to

 

M03_TXEN

B8

 

O

 

None

 

 

M04_TXEN

H4

 

 

 

Mxx_TCLK.

 

 

 

 

 

 

 

 

 

M05_TXEN

L1

 

 

 

 

 

 

 

 

 

M06_TXEN

V3

 

 

 

 

 

 

 

 

 

M07_TXEN

AE4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M00_TXER

D21

 

 

 

 

 

 

 

 

 

M01_TXER

A17

 

 

 

 

 

 

 

 

 

M02_TXER

D11

 

 

 

 

 

 

 

Transmit error. Allows coding errors to be propagated across the MII. Mxx_TXER is asserted

 

M03_TXER

C8

 

O

 

None

 

 

M04_TXER

H3

 

 

 

at the end of an under-running frame, enabling the TNETX4090 to force a coding error.

 

 

 

 

 

 

 

 

 

M05_TXER

N3

 

 

 

 

 

 

 

 

 

M06_TXER

V2

 

 

 

 

 

 

 

 

 

M07_TXER

AF4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MII management interface

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TERMINAL

 

I/O

 

INTERNAL

 

 

DESCRIPTION

 

NAME

NO.

 

 

RESISTOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MDCLK

K26

 

O

 

 

Pullup

 

Serial MII management data clock. Disabled [high-impedance (Z) state] through the use of the

 

 

 

 

 

serial input/output (SIO) register. An internal pullup resistor is provided.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MDIO

K25

 

I/O

 

 

Pullup

 

Serial MII management data input/output. Disabled [high-impedance (Z) state] through the use

 

 

 

 

 

of the SIO register. An internal pullup resistor is provided.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K24

 

O

 

 

Pullup

 

Serial MII management reset. Disabled [high-impedance (Z) state] through the use of the SIO

 

MRESET

 

 

 

 

 

 

 

 

 

register. An internal pullup resistor is provided.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

POST OFFICE BOX 655303 DALLAS, TEXAS 75265

Image 14
Contents Description MAC Eeprom CPU I/F MIIMAC MII DMAPCS Duplex LED Rdram Interface Jtag Interface GGP Package Bottom View Signal-to-Ball Mapping Signal Names Sorted Alphabetically Signal Ball NameReset Sdma SAD0 Control logic interface Terminal FunctionsJtag interface Terminal Internal Description Name RESISTOR²100-/1000-Mbit/s MAC interface Gmii mode M08TXD7 M08TXD6 M08TXD5Terminal Internal Description Name Resistor Port to not support pause frames 10-/100-Mbit/s MAC interface MII mode ports 0±7 PulldownM00RENEG M01RENEG ThunderSWITCH II 9-PORT 100-/1000-MBIT/S ETHERNET Switch M04TCLK M05TCLK M06TCLK M07TCLK AD4MII management interface Rdram interface DIO interface Eeprom interface100-/1000-Mbit/s port PCS LED interface Power supplyLED interface Byte DIO Address DIO interface descriptionDIO Internal Register Address Map ThunderSWITCH II 9-PORT 100-/1000-MBIT/S ETHERNET TNETX4090VLAN1QID VLAN0QID VLAN37QID VLAN36QID TNETX4090 PCS8Status PCS8Control 0x0700 DIO interface description Port no Head Statistic Even ODD Ports Port StatisticsTail Port no Head Statistic Tail 0x90ExAddress-Lookup Statistics DMA Interface SignalsSignal Description Receiving/transmitting management framesDIO Interface State During Hardware Reset State of DIO signal terminals during hardware resetDIO Interface During Hardware Reset Ieee Std 802.1Q Vlan tags on the NM portTpid TCI Vlan IDFCS CRCTNETX4090 NM bandwidth and priority PHY management interfaceFull-duplex NM port Interrupt processingMAC interface Backoff Adaptive performance optimization APOInterframe gap enforcement Receive versus transmit priority10-/100-Mbit/s MII ports 0±7 Speed, duplex, and flow-control negotiation100-Mbit/s Port Negotiation With the TNETE2104 100-/1000-Mbit/s PHY interface port Full-duplex hardware flow control Port 8 Duplex Negotiation in MII ModePort 8 Pause Negotiation in MII Mode OutcomeM08GTCLK M08TXEN Pretagging and extended port awarenessPretag on transmission Learning Format Receive Pretag Bit Definitions Transmit Pretag Bit DefinitionsPretag on reception BIT Name FunctionRXD Flow COL TXD Directed Format Receive Pretag Bit DefinitionsRing-cascade topology TNETX4090 RXD Flow COL TXDM08GTCLK M08TXEN M08RXDV Switch TerminalRing-Topology Connectivity GND SCL SDAEdio TNETX4090 Eclk Summary of Eeprom load outcomes Outcome Stop Load Initd ² Fault LED EclkInteraction of Eeprom load with the SIO register Collision LED States Compatibility with future device revisionsPort LED States State DisplayLamp test PCS duplex LEDLED Status Bit Definitions and Shift Order Multi-LED displayTNETX4090 VCC NC Txclk Vref Rxclk VDD BUS Enable GND BUS Ctrl Rdram SINBUS Enable GND Rdram BUS Ctrl SIN Sout SCHAIN0 Txclk Vref Rxclk VDDRacbist instruction Jtag Instruction OpcodesHighz instruction Jtag Bist StatusIale Frame routingVlan support Ieee Std 802.1Q header ± transmission Address maintenanceIeee Std 802.1Q tags ± reception Spanning-tree supportAging algorithms Frame-Routing Algorithm SPWS044E ± December 1997 ± Revised August Port routing code Port trunking/load sharing Removal of source portTrunk Group 1 Port Membership Trunk1Ports Register Port trunking exampleTrunk Group 0 Port Membership Trunk0Ports Register Extended port awarenessFlow control Multicast limit Other flow-control mechanismsHardware flow control System test capabilitiesReading Rdram Internal wrap testDuplex wrap test PHY TNETX4090Recommended operating conditions MIN NOM MAX UnitTiming requirements over recommended operating conditions Jtag interface Control signalsReset see Figure Physical medium attachment interface port Receive PMA receive see FigureTransmit PMA transmit see FigureGmii transmit see Figure Gmii portGmii receive see Figure PMA and Gmii clock see Figure Gmii ClockMII ports 0±8 MII receive see FigureMII transmit see Figure MII clock see FigureDtxclk Drxclk Rdram interfaceRdram see Figure Dbusctrl DbusenSCS Srnw SAD1±SAD0 Sdma SDATA7± SDATA0 Srdy Sint DIO interfaceDIO and DMA writes see Figure DIO and DMA reads see Figure SCS Srnw SAD1±SAD0 Sdma SDATA7± SDATA0 SrdyEeprom reads see Figure Eeprom interfaceEeprom writes see Figure Ledclk Leddata LED interfaceLED see Figure VOH VOLTTL Output Macro Propagation-Delay-Time Voltage Waveforms VOL VDD VDD VOH50% Lvcmos Mechanical Data TNETX4090GGP Obsolete BGA TBDImportant Notice