M4557 - Model 9210 Nitriding Controller

Loops Display

The current process variable for the active loops is displayed on the left. The setpoint for each parameter is to the right of the process variable, with the % control output to the right of the setpoint column.

The “loops” screen also allows you to move back to the default “Status” screen. By pressing the “status” button on the bottom right-hand side of the operator interface. Pressing the Program button will open the “Program” screen.

Temp Detail

This screen is activated by pressing the Temp Detail button on the Loops Display screen.

The operator can change the temperature setpoint by touching the temperature setpoint on the screen next to the words “Setpoint”. When pressing the setpoint box, a numeric keypad is displayed, showing the current value and allowing you to enter a new setpoint by simply pressing on the appropriate numeric keys. Once the correct setpoint has been entered, press the Enter key to make the change. When the Enter key is pressed, the display returns to the “Temperature Detail” screen. The other active buttons - Auto/Manual and Output - are used in the same way. Pressing the Auto/Manual button will cycle the controller mode between auto and manual. Depending on the current Login, the

screen may prompt for the Supervisor or Administrator password before the mode can be changed. Pressing the Output button displays an alphanumeric keypad that allows the operator to change the % Output (as long as the controller mode as been changed to manual. Entering the % output (while in manual mode) changes the % control output. This is especially useful when setting the linkage on motors, or testing the range of motion of an electric actuator.

The Temp, % Dissociation and Back Pressure detail screens are used in the manner discussed above.

SSi Manual SERIES 9210-M4557-Nitriding

Page 13 of 13

Image 13
Contents SSi’s Nitriding Control System Table of Contents M4557 Model 9210 Nitriding Controller Safety M4557 Model 9210 Nitriding Controller Controller Description About This ManualModel 9210 Terminals Connections Ethernet Connections Flash Card & Flash Card Reader Electrical InstallationOperator Interface Screen Saver Nitriding Control System Mode of Operation Copper Brass Galvanized Steel Aluminum Installation Mounting Stand-alone Flow PanelTouch-screen Interface Temp Detail Loops DisplayMenu Display Menus M4557 Model 9210 Nitriding Controller Program Display Alarm Ack ChartData Logging using Flash Card M4557 Model 9210 Nitriding Controller Program Edit Configuration Configuration MenuParameter Value Shutdown Display Auxiliary Analog InputDate and Time Slave Communications StatusManual Event Control PID Loop SetupChange setpoint overshoot protection Zone / Load TC Setup Event Run Program SetupInstrument Setup Port SetupZone Assignments Step Opcode Temperature Atmosphere OptionNone BP Back Pressure Temp Furnace SetupInternal Loop Instrument 1 Instrument Internal LoopInternal Instrument 1 Instrument Default Wait LimitsFurnace Name Relay Assignment Alarm SetupRelay Set Points Analog Input SetupAnalog Output Setup IP Address Passcode and AlarmEvent Control Valve Setup M4557 Model 9210 Nitriding Controller Zero Output Menu Item Security Level Read/Write Raw Data Analog Input Board Setup AUX SP Configuration Programs Overview M4557 Model 9210 Nitriding Controller Opcodes Series 9210 Opcodes Programmer DescriptionM4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller Typical Nitriding Instrument Designations Applications Information Standard Event AssignmentsRecipe Step OpCode Temp OptionsJump Recipe Vessel Pressure Switches High and Low Pressure SwitchesFlow Section Nitriding Gas Supply Sample PortsMass Flow Meters Flow Head UnitGas Solenoids Differential Pressure Transmitter Back Pressure ValveDrip Legs Sample Cell SolenoidM4557 Model 9210 Nitriding Controller System Description Display NA Analog outputs isolated Optional SpecificationSensor General Frequency Technical Information Data=xCRLF Error messages System errors Nitriding Sample Cell cleaning TC Type Range in mV E80 J80 K80 N80 NNM MCO # Revision History Description Date