M4557 - Model 9210 Nitriding Controller
•Event Control
•Valve Configuration
•Valve Setup
•User Calibration
•Full Calibration
•Set Menu Security
•Read/Write Raw Data
•Curve Entry
•Alternate PID Setup
•Analog Input Board Setup
•PLC Calibration
•ADAM Correction
•AUX SP Configuration
Menus
There are four levels of menus in the Series 9210.
•The first level is the operator level. These are functions or operations that are typically handled by the furnace operator. This menu is accessed without the need for a pass code.
•The second level is to be used by a supervisor. This level requires entry of the level 1 or level 2 pass code.
•The third level is the Administrator level. This requires the level 2 pass code ONLY.
•The fourth level is the SSi level. This requires a special passcode that can only by obtained by calling SSi at
As shipped, the level 1 and level 2 codes are set as 1 and 2 respectively. The pass codes can be changed under the Passcode and Alarm menu option.
The Menu screen has five operating buttons located on the right side of the screen. The Up arrow moves the cursor from bottom to top. The Enter button activates the highlighted selection that the operator has chosen, the Down arrow key moves the cursor from top to bottom, the Login key activates another screen that allows access to the user to enter a passcode to set the user level, and the Esc key takes you back to the previous screen without any action being taken.
The selections on the menu that are generally used by the furnace operator are:
•Program Run
•Slave Communications Status.
•Manual Event Control.
•Zone/Load TC Setup.
•Shutdown
The Program Run screen allows the operator to start/stop/hold/continue recipes, as well as adjust soak time values.
The Slave Communications Status allows the operator to view the communications status with slave instruments.