M4557 - Model 9210 Nitriding Controller

Furnace Setup

The “Nitrider Mode” selection will allow the user to select the specific Nitriding mode:

H2 and Dissociation

NH3 and Dissociation

H2, NH3 and Dissociation

H2, NH3 and Nit. Potential

H2 and Nit. Potential

NH3 and Nit. Potential

H2 and H2 Control

NH3 and NH3 Control

The “H2 Cell Type” selection will allow the user to set the H2 cell type. It can be either Hi or H2.

The “H2 RS-232 Comms” selection will allow the user to know if there are RS-232 communications. It can be either Yes or No.

The “Temp display” selection will allow the user to set the temperature display source. It can be either Internal or SPP Instrument.

The “LP3 Control” selection allows the user to set the loop 3 control factor:

None

BP (Back Pressure)

N/A

Temp

The “N2 Valve” selection will allow the user to set the N2 valve. It can be either Yes or No. The “NH3 Valve” selection will allow the user to set the NH3 valve. It can be either Yes or No.

The “D.A. Valve” selection will allow the user to set the Dissociated Ammonia valve. It can be either Yes or No.

The “Aux Valve” selection will allow the user to set the auxiliary valve. It can be either Yes or No. The “Temperature Mode” selection will allow the user to set the temperature mode. It can be either °F (Fahrenheit) or °C (Celsius).

The programmer section will allow the user to set up the different instruments for the programmer. The “Atm. Inst” selection will allow the user to set the atmosphere instrument:

Internal Loop 1

Internal Loop 2

Internal Loop 3

Instrument 1 – Instrument 25

The “Temp. Inst” selection will allow the user to set the temperature instrument:

Internal Loop 1

SSi Manual SERIES 9210-M4557-Nitriding

Page 26 of 26

Image 26
Contents SSi’s Nitriding Control System Table of Contents M4557 Model 9210 Nitriding Controller Safety M4557 Model 9210 Nitriding Controller About This Manual Controller DescriptionModel 9210 Terminals Connections Ethernet Connections Operator Interface Screen Saver Electrical InstallationFlash Card & Flash Card Reader Nitriding Control System Mode of Operation Installation Mounting Stand-alone Flow Panel Copper Brass Galvanized Steel AluminumTouch-screen Interface Loops Display Temp DetailMenu Display Menus M4557 Model 9210 Nitriding Controller Program Display Data Logging using Flash Card ChartAlarm Ack M4557 Model 9210 Nitriding Controller Parameter Value Configuration Configuration MenuProgram Edit Date and Time Auxiliary Analog InputShutdown Display Slave Communications StatusChange setpoint overshoot protection PID Loop SetupManual Event Control Event Run Program Setup Zone / Load TC SetupPort Setup Instrument SetupStep Opcode Temperature Atmosphere Option Zone AssignmentsInternal Loop Instrument 1 Instrument Furnace SetupNone BP Back Pressure Temp Internal LoopFurnace Name Default Wait LimitsInternal Instrument 1 Instrument Alarm Setup Relay AssignmentAnalog Input Setup Relay Set PointsAnalog Output Setup Passcode and Alarm IP AddressEvent Control Valve Setup M4557 Model 9210 Nitriding Controller Zero Output Menu Item Security Level Read/Write Raw Data Analog Input Board Setup AUX SP Configuration Programs Overview M4557 Model 9210 Nitriding Controller Series 9210 Opcodes Programmer Description OpcodesM4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller Recipe Step OpCode Temp Applications Information Standard Event AssignmentsTypical Nitriding Instrument Designations OptionsJump Recipe Flow Section Nitriding Gas Supply High and Low Pressure SwitchesVessel Pressure Switches Sample PortsGas Solenoids Flow Head UnitMass Flow Meters Drip Legs Back Pressure ValveDifferential Pressure Transmitter Sample Cell SolenoidM4557 Model 9210 Nitriding Controller System Description Specification Display NA Analog outputs isolated OptionalSensor General Frequency Technical Information Data=xCRLF Error messages System errors Nitriding Sample Cell cleaning TC Type Range in mV E80 J80 K80 N80 NNM Revision History Description Date MCO #