SSI America 9210 user manual System Description

Page 55

M4557 - Model 9210 Nitriding Controller

Super Systems Nitriding Sample Cell

1.0Introduction

1.1Applications

This Card is designed to be a Nitriding Sample Cell for Super Systems.

The unit is calibrated for either

(1)0 to 100% Hydrogen in a background of Methane and Carbon monoxide.

(2)0 to 75% Hydrogen in dissociated Ammonia (calibrated on 100% H2)

1.2System Description

The system comprises an electronic unit Consisting of two PCBs mechanically connected via pillars. The lower card provides power and process control options The secondary card with the Nitriding Sample Cell mounted on it offers the signal conditioning and communications port.

1.3System Highlights

The Unit is provided:

PCB mounted Nitriding Sample cell

RS232/485 Communications

.

ٛ.Voltage free contacts (optional)

ٛ.a. High alarm 1:-option

ٛ.b. High alarm 2:- option

. Isolated analog output (0…5V) Optional

. 24V power supply.

1.4Unpacking and Visual checking

Take all normal precautions when opening the packages. In particular, avoid the use of long bladed cutters. Check that all pipe connections have compression nuts and olives intact. Search packing if any are missing. Check for any sign of damage. Carefully remove any internal packing material.

SSi Manual SERIES 9210-M4557-Nitriding

Page 55 of 55

Image 55
Contents SSi’s Nitriding Control System Table of Contents M4557 Model 9210 Nitriding Controller Safety M4557 Model 9210 Nitriding Controller Controller Description About This ManualModel 9210 Terminals Connections Ethernet Connections Flash Card & Flash Card Reader Electrical InstallationOperator Interface Screen Saver Nitriding Control System Mode of Operation Copper Brass Galvanized Steel Aluminum Installation Mounting Stand-alone Flow PanelTouch-screen Interface Temp Detail Loops DisplayMenu Display Menus M4557 Model 9210 Nitriding Controller Program Display Alarm Ack ChartData Logging using Flash Card M4557 Model 9210 Nitriding Controller Program Edit Configuration Configuration MenuParameter Value Slave Communications Status Auxiliary Analog InputShutdown Display Date and TimeManual Event Control PID Loop SetupChange setpoint overshoot protection Zone / Load TC Setup Event Run Program SetupInstrument Setup Port SetupZone Assignments Step Opcode Temperature Atmosphere OptionInternal Loop Furnace SetupNone BP Back Pressure Temp Internal Loop Instrument 1 InstrumentInternal Instrument 1 Instrument Default Wait LimitsFurnace Name Relay Assignment Alarm SetupRelay Set Points Analog Input SetupAnalog Output Setup IP Address Passcode and AlarmEvent Control Valve Setup M4557 Model 9210 Nitriding Controller Zero Output Menu Item Security Level Read/Write Raw Data Analog Input Board Setup AUX SP Configuration Programs Overview M4557 Model 9210 Nitriding Controller Opcodes Series 9210 Opcodes Programmer DescriptionM4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller Options Applications Information Standard Event AssignmentsTypical Nitriding Instrument Designations Recipe Step OpCode TempJump Recipe Sample Ports High and Low Pressure SwitchesVessel Pressure Switches Flow Section Nitriding Gas Supply Mass Flow Meters Flow Head Unit Gas Solenoids Sample Cell Solenoid Back Pressure ValveDifferential Pressure Transmitter Drip LegsM4557 Model 9210 Nitriding Controller System Description Display NA Analog outputs isolated Optional SpecificationSensor General Frequency Technical Information Data=xCRLF Error messages System errors Nitriding Sample Cell cleaning TC Type Range in mV E80 J80 K80 N80 NNM MCO # Revision History Description Date