M4557 - Model 9210 Nitriding Controller

5.0TECHNICAL INFORMATION

The Nitriding Sample Cell is a device that produces an output that is a function of the thermal conductivity of the gas surrounding its sensor. Gases differ in their thermal conductivity and the thermal conductivity of a mixture is approximately the mathematical average of the thermal conductivity and concentration of each component. Because thermal conductivity is a bulk physical property of the gas its measurement is not specific for any component. The Model 9210 is programmed in such a way that it assumes the components are always the same species, e.g. oxygen, nitrogen and carbon dioxide. If a gas mixture containing other components is introduced into the sample cell it will not produce the correct readings.

6.0SERVICING

The Nitriding Sample Cell sensor is non-depleting and will last indefinitely if not subjected to misuse. The sensor can only be replaced by the use of specialist equipment and would have to be returned to Super Systems or their agent should a replacement be required.

Questions on the analyzer should be directed to Super Systems Inc. It is important that the serial number or job number are quoted. These numbers may be found on the data label on the rear panel.

Super Systems Inc

7205 Edington Drive

Cincinnati, OH 45249

513-772-0060, 800-666-4330

Fax: 513-772-9466

www.supersystems.com

SSi Manual SERIES 9210-M4557-Nitriding

Page 59 of 59

Image 59
Contents SSi’s Nitriding Control System Table of Contents M4557 Model 9210 Nitriding Controller Safety M4557 Model 9210 Nitriding Controller Controller Description About This ManualModel 9210 Terminals Connections Ethernet Connections Operator Interface Screen Saver Electrical InstallationFlash Card & Flash Card Reader Nitriding Control System Mode of Operation Copper Brass Galvanized Steel Aluminum Installation Mounting Stand-alone Flow PanelTouch-screen Interface Temp Detail Loops DisplayMenu Display Menus M4557 Model 9210 Nitriding Controller Program Display Data Logging using Flash Card ChartAlarm Ack M4557 Model 9210 Nitriding Controller Parameter Value Configuration Configuration MenuProgram Edit Slave Communications Status Auxiliary Analog InputShutdown Display Date and TimeChange setpoint overshoot protection PID Loop SetupManual Event Control Zone / Load TC Setup Event Run Program SetupInstrument Setup Port SetupZone Assignments Step Opcode Temperature Atmosphere OptionInternal Loop Furnace SetupNone BP Back Pressure Temp Internal Loop Instrument 1 InstrumentFurnace Name Default Wait LimitsInternal Instrument 1 Instrument Relay Assignment Alarm SetupRelay Set Points Analog Input SetupAnalog Output Setup IP Address Passcode and AlarmEvent Control Valve Setup M4557 Model 9210 Nitriding Controller Zero Output Menu Item Security Level Read/Write Raw Data Analog Input Board Setup AUX SP Configuration Programs Overview M4557 Model 9210 Nitriding Controller Opcodes Series 9210 Opcodes Programmer DescriptionM4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller Options Applications Information Standard Event AssignmentsTypical Nitriding Instrument Designations Recipe Step OpCode TempJump Recipe Sample Ports High and Low Pressure SwitchesVessel Pressure Switches Flow Section Nitriding Gas SupplyGas Solenoids Flow Head UnitMass Flow Meters Sample Cell Solenoid Back Pressure ValveDifferential Pressure Transmitter Drip LegsM4557 Model 9210 Nitriding Controller System Description Display NA Analog outputs isolated Optional SpecificationSensor General Frequency Technical Information Data=xCRLF Error messages System errors Nitriding Sample Cell cleaning TC Type Range in mV E80 J80 K80 N80 NNM MCO # Revision History Description Date