M4557 - Model 9210 Nitriding Controller

2.0SPECIFICATION

2.1Enclosure - NA

2.2Dimensions

Electronics unit: H. 180mm W.85mm D.60mm See figure 1.

2.3Ambient Temperature

Sensor unit: -10…50°C Max

2.4Display - NA

2.4Analog outputs – isolated (Optional)

4…20mAV proportional to 0..100% Hydrogen (minimum load 500 ohm.) Optional

2.5Alarm indicators (Optional)

Voltage free contacts SPDT Relay 1A /120Vac or 2A /240Vac

High alarm 1 relay (Set to 0.6% Hydrogen)

High alarm 2 relay (Set to 1.0% Hydrogen)

2.6Communications RS232

Set up: 9600 Baud, 1 start bit, 8 data bits, 1 stop bit, no parity, hardware (CTS/RTS) handshaking. See Appendix 1 for proposed communication protocol.

 

DTE male 9w

 

 

PIN

NAME

 

 

3

TX(out)

 

 

2

RX (in)

7RTS (out)

8CTS (in)

5GND

RS485

Optional

SSi Manual SERIES 9210-M4557-Nitriding

Page 56 of 56

Image 56
Contents SSi’s Nitriding Control System Table of Contents M4557 Model 9210 Nitriding Controller Safety M4557 Model 9210 Nitriding Controller About This Manual Controller DescriptionModel 9210 Terminals Connections Ethernet Connections Operator Interface Screen Saver Electrical InstallationFlash Card & Flash Card Reader Nitriding Control System Mode of Operation Installation Mounting Stand-alone Flow Panel Copper Brass Galvanized Steel AluminumTouch-screen Interface Loops Display Temp DetailMenu Display Menus M4557 Model 9210 Nitriding Controller Program Display Data Logging using Flash Card ChartAlarm Ack M4557 Model 9210 Nitriding Controller Parameter Value Configuration Configuration MenuProgram Edit Auxiliary Analog Input Shutdown DisplayDate and Time Slave Communications StatusChange setpoint overshoot protection PID Loop SetupManual Event Control Event Run Program Setup Zone / Load TC SetupPort Setup Instrument SetupStep Opcode Temperature Atmosphere Option Zone AssignmentsFurnace Setup None BP Back Pressure TempInternal Loop Instrument 1 Instrument Internal LoopFurnace Name Default Wait LimitsInternal Instrument 1 Instrument Alarm Setup Relay AssignmentAnalog Input Setup Relay Set PointsAnalog Output Setup Passcode and Alarm IP AddressEvent Control Valve Setup M4557 Model 9210 Nitriding Controller Zero Output Menu Item Security Level Read/Write Raw Data Analog Input Board Setup AUX SP Configuration Programs Overview M4557 Model 9210 Nitriding Controller Series 9210 Opcodes Programmer Description OpcodesM4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller Applications Information Standard Event Assignments Typical Nitriding Instrument DesignationsRecipe Step OpCode Temp OptionsJump Recipe High and Low Pressure Switches Vessel Pressure SwitchesFlow Section Nitriding Gas Supply Sample PortsGas Solenoids Flow Head UnitMass Flow Meters Back Pressure Valve Differential Pressure Transmitter Drip Legs Sample Cell SolenoidM4557 Model 9210 Nitriding Controller System Description Specification Display NA Analog outputs isolated OptionalSensor General Frequency Technical Information Data=xCRLF Error messages System errors Nitriding Sample Cell cleaning TC Type Range in mV E80 J80 K80 N80 NNM Revision History Description Date MCO #