SSI America 9210 user manual Passcode and Alarm, IP Address

Page 31

M4557 - Model 9210 Nitriding Controller

Loop 2 Dec

Loop 2 Combo

PV 3 retrans

Loop 3 Inc

Loop 3 Dec

Loop 3 Combo

Input 1 retrans

Input 2 retrans

Input 3 retrans

Input 4 retrans

The “Offset” selection will allow the user to set the offset. This will display a numeric keypad. This will range from –9999to 9999.

The “Range” selection will allow the user to set the range of the output. This will display a numeric keypad. This will range from –9999to 9999.

Pressing the Esc key returns you to the configuration menu.

Passcode and Alarm

Parameter

Value

Level 1 Code

1

Level 2 Code

2

Web Level 1 Code

111

Web Level 2 Code

222

Web Change Enable

1

No Alarm

Contact is Open

Alarm Text Setup

 

Alarm 0 – Alarm 99

User Alarm xx

The values shown in the above table are the default values. The parameter “No Alarm” means that if there is NO CONTROLLER ALARM, the controller alarm relay is NO. The “Level 1 Code” and the “Level 2 Code” selections will allow the user to set the Supervisor and Administration passcodes, respectively. Either of these options will display a numeric keypad that will range from 0 to 9999. The “Web Level 1 Code” and the “Web Level 2 Code” selections will allow the user to set the Supervisor and Administration passcodes, respectively, for the 9210’s web page. Either of these options will display a numeric keypad that will range from 0 to 9999. The “Web Change Enable” selection will allow the user determine if changes can be made to the instrument through the web page. This will display a numeric keypad that can be either 1 (Change OK) or 0 (No Change Allowed). The “No Alarm” selection will allow the user to set what the no alarm state is. This will display a numeric keypad that can be either 0 (Contact is Open) or 1 (Contact is Closed). This allows the operator to assign the controller alarm as a NC contact such as a 1400°F alarm. The “Alarm Text Setup” section will allow the user to set the alarm text for up to ninety-nine user alarms. Any of these options will display an alphanumeric keypad.

Press the Esc key to return to the configuration menu.

IP Address

Parameter

Value

IP Address 1

192

IP Address 2

168

IP Address 3

0

IP Address 4

200

IP Address Mask 1

255

IP Address Mask 2

255

SSi Manual SERIES 9210-M4557-Nitriding

Page 31 of 31

Image 31
Contents SSi’s Nitriding Control System Table of Contents M4557 Model 9210 Nitriding Controller Safety M4557 Model 9210 Nitriding Controller Controller Description About This ManualModel 9210 Terminals Connections Ethernet Connections Flash Card & Flash Card Reader Electrical InstallationOperator Interface Screen Saver Nitriding Control System Mode of Operation Copper Brass Galvanized Steel Aluminum Installation Mounting Stand-alone Flow PanelTouch-screen Interface Temp Detail Loops DisplayMenu Display Menus M4557 Model 9210 Nitriding Controller Program Display Alarm Ack ChartData Logging using Flash Card M4557 Model 9210 Nitriding Controller Program Edit Configuration Configuration MenuParameter Value Slave Communications Status Auxiliary Analog InputShutdown Display Date and TimeManual Event Control PID Loop SetupChange setpoint overshoot protection Zone / Load TC Setup Event Run Program SetupInstrument Setup Port SetupZone Assignments Step Opcode Temperature Atmosphere OptionInternal Loop Furnace SetupNone BP Back Pressure Temp Internal Loop Instrument 1 InstrumentInternal Instrument 1 Instrument Default Wait LimitsFurnace Name Relay Assignment Alarm SetupRelay Set Points Analog Input SetupAnalog Output Setup IP Address Passcode and AlarmEvent Control Valve Setup M4557 Model 9210 Nitriding Controller Zero Output Menu Item Security Level Read/Write Raw Data Analog Input Board Setup AUX SP Configuration Programs Overview M4557 Model 9210 Nitriding Controller Opcodes Series 9210 Opcodes Programmer DescriptionM4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller Options Applications Information Standard Event AssignmentsTypical Nitriding Instrument Designations Recipe Step OpCode TempJump Recipe Sample Ports High and Low Pressure SwitchesVessel Pressure Switches Flow Section Nitriding Gas SupplyMass Flow Meters Flow Head UnitGas Solenoids Sample Cell Solenoid Back Pressure ValveDifferential Pressure Transmitter Drip LegsM4557 Model 9210 Nitriding Controller System Description Display NA Analog outputs isolated Optional SpecificationSensor General Frequency Technical Information Data=xCRLF Error messages System errors Nitriding Sample Cell cleaning TC Type Range in mV E80 J80 K80 N80 NNM MCO # Revision History Description Date