SSI America 9210 user manual Event Control

Page 32

M4557 - Model 9210 Nitriding Controller

IP Address Mask 3

255

IP Address Mask 4

0

IP Address Gateway 1

192

IP Address Gateway 2

168

IP Address Gateway 3

1

IP Address Gateway 4

1

 

 

Highlighting the parameter that needs to be entered and pressing the Enter button displays a numeric keypad that can be used to enter the required value. This will range from 0 to 256.

The default IP address is: 192.168.0.200

The default IP Address Gateway is: 192.168.1.1

Pressing the Esc key returns you to the configuration menu.

Event Control

This menu option will allow the user to set up the event control for the 9210. The “Hold Instrument Number” selection will display a numeric keypad that can range from 0 to 11. The “Hold Minimum PV” selection will display a numeric keypad that will range from 0 to 4000. The “Hold Maximum PV” selection will display a numeric keypad that will range from 0 to 4000. The “Event for Program Run” selection will display a numeric keypad that will range from –1to 15. A value of – 1 means there is no event. The “Event for Program Reset” selection will display a numeric keypad that will range from –1to 15. A value of – 1 means there is no event. The “Event 0” through “Event 15” selection will allow the user to assign the specific events. The list of options for this

selection is:

Event Inactive

Event Active, Open Triggers Hold

Event Active, Closed Triggers Hold

Valve Configuration

This screen provides setup information for the 9210 on the flow controller boards.

The “Decimal Place” selection determines how the 9210 will display gas flows. This will display a numeric keypad that can range from 0 to 4.

The “Valve Control Mode” selection determines how the 9210 will adjust gas flows if required for %Dissociation. This will display a screen that will allow the user to select the mode. The choices are:

Individual Trim

Flow

Ratio

Auto

The “D.A. Switch Point” selection determines the

control switch point for switching the atmosphere display from %Dissociation to Kn. This will display a

SSi Manual SERIES 9210-M4557-Nitriding

Page 32 of 32

Image 32
Contents SSi’s Nitriding Control System Table of Contents M4557 Model 9210 Nitriding Controller Safety M4557 Model 9210 Nitriding Controller About This Manual Controller DescriptionModel 9210 Terminals Connections Ethernet Connections Operator Interface Screen Saver Electrical InstallationFlash Card & Flash Card Reader Nitriding Control System Mode of Operation Installation Mounting Stand-alone Flow Panel Copper Brass Galvanized Steel AluminumTouch-screen Interface Loops Display Temp DetailMenu Display Menus M4557 Model 9210 Nitriding Controller Program Display Data Logging using Flash Card ChartAlarm Ack M4557 Model 9210 Nitriding Controller Parameter Value Configuration Configuration MenuProgram Edit Auxiliary Analog Input Shutdown DisplayDate and Time Slave Communications StatusChange setpoint overshoot protection PID Loop SetupManual Event Control Event Run Program Setup Zone / Load TC SetupPort Setup Instrument SetupStep Opcode Temperature Atmosphere Option Zone AssignmentsFurnace Setup None BP Back Pressure TempInternal Loop Instrument 1 Instrument Internal LoopFurnace Name Default Wait LimitsInternal Instrument 1 Instrument Alarm Setup Relay AssignmentAnalog Input Setup Relay Set PointsAnalog Output Setup Passcode and Alarm IP AddressEvent Control Valve Setup M4557 Model 9210 Nitriding Controller Zero Output Menu Item Security Level Read/Write Raw Data Analog Input Board Setup AUX SP Configuration Programs Overview M4557 Model 9210 Nitriding Controller Series 9210 Opcodes Programmer Description OpcodesM4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller M4557 Model 9210 Nitriding Controller Applications Information Standard Event Assignments Typical Nitriding Instrument DesignationsRecipe Step OpCode Temp OptionsJump Recipe High and Low Pressure Switches Vessel Pressure SwitchesFlow Section Nitriding Gas Supply Sample PortsGas Solenoids Flow Head UnitMass Flow Meters Back Pressure Valve Differential Pressure TransmitterDrip Legs Sample Cell SolenoidM4557 Model 9210 Nitriding Controller System Description Specification Display NA Analog outputs isolated OptionalSensor General Frequency Technical Information Data=xCRLF Error messages System errors Nitriding Sample Cell cleaning TC Type Range in mV E80 J80 K80 N80 NNM Revision History Description Date MCO #