Light Output:

 

 

 

 

Day Intensity

270,000 ±25% effective candelas, single flash

 

Twilight Intensity

20,000 ±25% effective candelas, single flash

 

Night Intensity

2,000 ±25% effective candelas, burst of flashes

 

Beam Pattern

 

120º horizontally, 3 º min. vertically

 

 

 

 

max. intensity of 3% of peak at -10º

 

Flash Rate: Day

 

40 fpm - single white flash

 

Twilight

 

40 fpm - single white flash

 

Night

 

40 fpm - white burst of flashes

 

Master/Slave Operation

Up to 24 slave SGF-60 Flashheads may share a common

 

 

sync and photocell circuit from one SGC-60 Master Controller.

Electrical Input:

 

 

 

 

Master Controller

50 Watts. 120, 208, 240, 277, 380, 480 VAC. 50, 60Hz

 

Flashhead

500 Watts. 120, 208, 240, 277, 380, 480 VAC. 50, 60Hz

 

 

 

Requires specific voltage selector block and manual

 

 

 

change to transformer wiring for different AC voltages.

Mechanical Properties:

 

 

 

 

Flashhead

 

 

 

 

Weight

 

82 pounds (37.2 kg)

 

Dimensions

18.88"w (479.4mm) x 15.25"h (387.4mm) x 10.75"d (273.1mm)

 

Surface Area

 

1.89 square feet

 

Wind Load

 

100 pounds at 150 mph (240kph)

 

Master Controller

 

 

 

 

Weight ………………………………………………………

 

........24 pounds (10.89 kg)

 

Dimensions

14"w (356mm) x 12"h (305mm) x 6"d (152mm)

Operating Environment:

 

 

 

 

Operating Temperature

 

-55ºC to +55ºC

 

Humidity

 

95% relative humidity

System Operating Status Indicators:

 

 

Flashhead, AC line power present

PWR ON Indicator DS1

 

Flashhead, high voltage present on capacitors

High Voltage Indicator DS1

 

(located on Trigger / High Voltage board)

 

 

Master Controller Indicators

 

 

 

Flashhead Status

 

LEDs DS1 - DS24, red/green

 

Day Mode

 

LED DS25 red

 

Twilight Mode

 

LED DS26 red

 

Night Mode

 

LED DS27 red

SG-60 High Intensity Strobe System

1-6

Manual EPM-00000019 Rev A

Image 14
Contents Manual Number EPM-00000019-001 Union Place Simi Valley, CA Phone 805 Fax 805Rev Comment Approved DateDisclaimers Table of Contents Troubleshooting Maintenance Safety Information Qualified Personnel EPM-00000019-001 Vii Rev a Scope General DescriptionModel SGC-60 Master Controller Model SGF-60 Flashhead Safety Precautions Airport Systems Specifications Flashhead Fail System Configuration System Controls Power ConfigurationConfiguration Switches Airport Systems Condition 1 You have a Catenary System Flashtube Installation Flashtube Installation Setting the Flashhead Elevation Airport Systems Master Controller Mounting Dimensions Flashhead Outline and Mounting Dimensions Installation Wiring Typical Wiring InstallationRed wire Photocell Black wire PhotocellWhite wire Photocell Blue wireMaster Controller TB5-NO4 Controlling the Red Light SystemMaster Controller TB3-C4 Responding to Top Red Beacon Failures9LCA Alarm Card C1 9LCA Alarm Card NC1Flex Conduit Typical Installation Layout Procedures for installation of conduit and tower wiringAirport Systems Airport Systems Flex Conduit Installation Junction Box Wiring Details Flex Conduit Installation Detail Splicing Details for WC000001 Cable WC000001 Cable OverviewAirport Systems Airport Systems 10 Flashhead Cable 10 Master Controller Circuit Board 11 Flashhead Digital Control Board Final Installation Check Power Up and System Tests If SW2-2 is set for an External RED system ON, then If SW2-2 is set for no External RED system OFF thenDay Mode Twilight Mode Night ModeAirport Systems Airport Systems Airport Systems Overall Description SGF-60 FlashheadAirport Systems Airport Systems Power Supplies CommunicationsMode Selection Flash Control Flash FeedbackHigh Voltage Rectification Flashtube TriggeringSGC-60 Master Controller Airport Systems Airport Systems Master Controller Board Schematic SGF-60 Flashhead System Schematic SGF-60 Digital Board Schematic SGF-60 Trigger/High-Voltage Board Schematic Troubleshooting RLC General Troubleshooting All Flashheads Stuck in Day Mode General Troubleshooting Flashhead Does Not Flash General Troubleshooting Flashhead Stuck in Day Mode Dual System-Specific Troubleshooting Catenary System-Specific Troubleshooting Chart SGC-60 Replacement Transformer White wire to the outer bottom right terminal Flashtube Installation Ambient Light Sensor Photocell Replacement Parts Description Part NumberSG-60 AOL Power Supply Component Location SG-60 AOL Flashhead Mounting Dimensions SG-60 AOL Power Supply Mounting Dimensions SG-60 AOL Wiring Installation SG-60 AOL Flashhead Component Locations SG-60 AOL Power Supply Component Locations SG-60 AOL Schematic