Honeywell SG-60 installation and operation guide Condition 1 You have a Catenary System

Page 19

Airport Systems

2.2.2.1Power Configuration

The Flashhead(s) are factory set for the correct AC input line voltage. However, the user shall verify that the AC line voltage selector block (located on the transformer board on top of transformer T1, Figure 1-2, Page 1-3) is labeled with the correct AC line voltage used at the site. For example, voltage selector block part number 77-3319 is labeled for 120VAC. If the voltage selector block is not labeled for the correct AC line voltage used at the site, the correct voltage selector block must be obtained from Honeywell, and the AC input wiring to transformer T2 must also be verified and corrected if necessary according to Figure 3-2, Page 3-12.

2.2.2.2Configuration Switches

SW1 – (Figure 2-11, Item 2, Page 2-26) This switch is used to reset the processor

§Press and hold – resets the processor and tests the automatic power reset circuit. Press and hold SW1 until the 5v power indicator (DS1, Figure 2-11, Item 1, Page 2-26) turns OFF momentarily then release.

SW2 – (Figure 2-11, Item 4, Page 2-26) This switch is used to set special operation options. Set all four switches to OFF unless your system meets one of the two conditions below:

CONDITION 1: You have a Catenary System

§SW2-1 – Set ON for all Flashheads on top level of a Catenary installation.

§SW2-2 – Set ON for all Flashheads on bottom level of Catenary installation.

§SW2 -1 & -2 – Set both to ON for all Flashheads on middle level of a Catenary installation.

CONDITION 2: You have Dual (Red/White) system with an older-model Master Controller.

§SW2-3 – Set to ON. This is provided for backward compatibility with older installations only. For new installations this switch is always OFF. For older white-only installations this switch is also OFF. To determine if an existing installation has an older Master Controller, refer to the new Master Controller in Figure 2-10, Page 2-25. Older Master Controllers do not have terminals TB5-TB9, or an EXT RED switch SW2-2 (Item 2 in the figure).

Note: Switch SW2-4 is a spare reserved for future use.

SG-60 High Intensity Strobe System

2-4

Manual EPM-00000019 Rev A

Image 19
Contents Union Place Simi Valley, CA Phone 805 Fax 805 Manual Number EPM-00000019-001Approved Date Rev CommentDisclaimers Table of Contents Troubleshooting Maintenance Safety Information Qualified Personnel EPM-00000019-001 Vii Rev a General Description ScopeModel SGC-60 Master Controller Model SGF-60 Flashhead Safety Precautions Airport Systems Specifications Flashhead Fail System Configuration Configuration Switches Power ConfigurationSystem Controls Airport Systems Condition 1 You have a Catenary System Flashtube Installation Flashtube Installation Setting the Flashhead Elevation Airport Systems Master Controller Mounting Dimensions Flashhead Outline and Mounting Dimensions Typical Wiring Installation Installation WiringBlue wire Black wire PhotocellWhite wire Photocell Red wire PhotocellResponding to Top Red Beacon Failures Controlling the Red Light SystemMaster Controller TB3-C4 Master Controller TB5-NO49LCA Alarm Card NC1 9LCA Alarm Card C1Procedures for installation of conduit and tower wiring Flex Conduit Typical Installation LayoutAirport Systems Airport Systems Flex Conduit Installation Junction Box Wiring Details Flex Conduit Installation Detail WC000001 Cable Overview Splicing Details for WC000001 CableAirport Systems Airport Systems 10 Flashhead Cable 10 Master Controller Circuit Board 11 Flashhead Digital Control Board Final Installation Check Power Up and System Tests If SW2-2 is set for no External RED system OFF then If SW2-2 is set for an External RED system ON, thenDay Mode Night Mode Twilight ModeAirport Systems Airport Systems Airport Systems SGF-60 Flashhead Overall DescriptionAirport Systems Airport Systems Communications Power SuppliesMode Selection Flash Feedback Flash ControlFlashtube Triggering High Voltage RectificationSGC-60 Master Controller Airport Systems Airport Systems Master Controller Board Schematic SGF-60 Flashhead System Schematic SGF-60 Digital Board Schematic SGF-60 Trigger/High-Voltage Board Schematic Troubleshooting RLC General Troubleshooting All Flashheads Stuck in Day Mode General Troubleshooting Flashhead Does Not Flash General Troubleshooting Flashhead Stuck in Day Mode Dual System-Specific Troubleshooting Catenary System-Specific Troubleshooting Chart SGC-60 Replacement Transformer White wire to the outer bottom right terminal Flashtube Installation Ambient Light Sensor Photocell Description Part Number Replacement PartsSG-60 AOL Power Supply Component Location SG-60 AOL Flashhead Mounting Dimensions SG-60 AOL Power Supply Mounting Dimensions SG-60 AOL Wiring Installation SG-60 AOL Flashhead Component Locations SG-60 AOL Power Supply Component Locations SG-60 AOL Schematic