Airport Systems

The charts assume that that you have already eliminated these as possible causes for the observed problem.

The charts may instruct you to make temporary changes for testing (such as select operating modes manually, or installing a jumper). These temporary measures are marked with rectangles with rounded corners. Always return the systems to their

normal state after completing your troubleshooting. To reduce chart complexity,

the charts not specify the individual actions necessary.

Multiple strobe problems are most commonly cause by faults in the communications cabling. If you have determined that there is a short or break, we recommend disconnecting communication wiring leading to the upper sections of the tower while checking and/or repairing the lower sections. Individual flashheads may be isolated in the same way. Using this technique, work upward from one flashhead level to the next, to create known good wiring (per Section 2.5.4).

If the cable test shows an open between TB5-A and TB5-B even though a terminator is set in a top-most strobe, then there is a break in either the A or B line. Use the following test to determine if the break is above or below a Flashhead level.

1.Remove all power from Flashheads and Master Controller at the main circuit breakers.

2.Unplug Data Cable connector TB5 from PCB1 in Master Controller.

3.In one of the Flashheads on a given level, install a jumper (or alligator clip) between TB1-4 and TB1-5.

4.Verify short circuit between (<20 ohms) TB5-A and TB5-B (both on Data Cable). If the measurement is open instead, the break is below that Flashhead level.

5.Remove the jumper between TB1-4 and TB1-5.

6.Plug Data Cable Connector TB5 back into PCB1.

The Troubleshooting charts use the following abbreviations:

FH

Flashhead

MC

Master Controller

DB

Digital Board (inside the SGF-60 Flashhead)

THVB Trigger/High-Voltage Board (inside the SGF-60 Flashhead)

RLC

Red-Light Controller (such as Honeywell’s 9LCA series).

SG-60 High Intensity Strobe System

4-2

Manual EPM-00000019 Rev A

Image 65
Contents Union Place Simi Valley, CA Phone 805 Fax 805 Manual Number EPM-00000019-001Approved Date Rev CommentDisclaimers Table of Contents Troubleshooting Maintenance Safety Information Qualified Personnel EPM-00000019-001 Vii Rev a General Description ScopeModel SGC-60 Master Controller Model SGF-60 Flashhead Safety Precautions Airport Systems Specifications Flashhead Fail System Configuration System Controls Power ConfigurationConfiguration Switches Airport Systems Condition 1 You have a Catenary System Flashtube Installation Flashtube Installation Setting the Flashhead Elevation Airport Systems Master Controller Mounting Dimensions Flashhead Outline and Mounting Dimensions Typical Wiring Installation Installation WiringWhite wire Photocell Black wire PhotocellRed wire Photocell Blue wireMaster Controller TB3-C4 Controlling the Red Light SystemMaster Controller TB5-NO4 Responding to Top Red Beacon Failures9LCA Alarm Card NC1 9LCA Alarm Card C1Procedures for installation of conduit and tower wiring Flex Conduit Typical Installation LayoutAirport Systems Airport Systems Flex Conduit Installation Junction Box Wiring Details Flex Conduit Installation Detail WC000001 Cable Overview Splicing Details for WC000001 CableAirport Systems Airport Systems 10 Flashhead Cable 10 Master Controller Circuit Board 11 Flashhead Digital Control Board Final Installation Check Power Up and System Tests If SW2-2 is set for no External RED system OFF then If SW2-2 is set for an External RED system ON, thenDay Mode Night Mode Twilight ModeAirport Systems Airport Systems Airport Systems SGF-60 Flashhead Overall DescriptionAirport Systems Airport Systems Communications Power SuppliesMode Selection Flash Feedback Flash ControlFlashtube Triggering High Voltage RectificationSGC-60 Master Controller Airport Systems Airport Systems Master Controller Board Schematic SGF-60 Flashhead System Schematic SGF-60 Digital Board Schematic SGF-60 Trigger/High-Voltage Board Schematic Troubleshooting RLC General Troubleshooting All Flashheads Stuck in Day Mode General Troubleshooting Flashhead Does Not Flash General Troubleshooting Flashhead Stuck in Day Mode Dual System-Specific Troubleshooting Catenary System-Specific Troubleshooting Chart SGC-60 Replacement Transformer White wire to the outer bottom right terminal Flashtube Installation Ambient Light Sensor Photocell Description Part Number Replacement PartsSG-60 AOL Power Supply Component Location SG-60 AOL Flashhead Mounting Dimensions SG-60 AOL Power Supply Mounting Dimensions SG-60 AOL Wiring Installation SG-60 AOL Flashhead Component Locations SG-60 AOL Power Supply Component Locations SG-60 AOL Schematic