Toshiba ste 58761 instruction manual Servo Free

Page 51

STE 58761

3.6SERVO FREE

(1)Function

Servo locks can be released for axes as desired when the guide movement mode is set to free. Axes in the servo free (i.e., unlocked) state can be moved freely by hand. This is convenient when moving the robot near workpieces and other such objects.

(2)Input format

None

(3)Comments

If You change from the servo free state to either the Test Operation Mode, the Internal Automatic Mode or the External Automatic Mode, the servo lock will be set for all axes.

The guide keys will only work while at least one of the deadman switches (on the back of the teach pendant) is pushed down.

If you move the robot by hand in the servo free state, other joints may move as well due to axial interference.

You cannot cancel the servo free state while in Feed Hold.

You can cancel the servo free state while displaying the Error History.

(4)Procedure

(a)Step 1: Select the Manual Mode

Turn the master mode switch on the control panel to "MANU".

(b)Step 2: Select the guide movement mode

Push the Guide Movement key on the teach pendant as many times as necessary to select "Free".

(c)Step 3: Release the servo locks

While pushing down on a deadman switch, push the guide keys on the minus (-) side to release the servo locks for the desired axes. Such axes will change over to the servo free state.

(d)Step 4: Guide the robot

Guide the robot by hand to where you want it to go.

(e)Step 5: Set the servo locks

3-7

Image 51
Contents Industrial Robot SR Series Operating Manual - i - Preface For European Union EU - iv - - v - - vi - -vii- -viii- - ix - Table of Contents Character INPUT・・・・・・・・・・・・・・・・・・・・・ Data INPUT・・・・・・・・・・・・・・・・・・・・・・・・・ Program SELECTION・・・・・・・・・・・・・・・・・・・ Direct EXECUTION・・・・・・・・・・・・・・・・・・・・・ Error DISPLAYS・・・・・・・・・・・・・・・・・・・・ Inputting Numeric Values for Joint LIMITS・・・・・・ - 1-1 - - 1-2 - Mode Structure Mspeed External Automatic ModeInternal Automatic Mode SelectManual Mode Edit Test Operation MachineStep Handling Disks Precautions for USE- 1-9 - Use of the Shift Key General OperationUse of the Function Keys Edit Load Save Testrun Reset NextCancelling an Entry Repeating an EntryCorrecting Incorrect Entries Use of Wild Cards ADATA. BAT ABC.PAR AfileABC.PAR ACD.DAT AAA Format for Operating Instructions Assigning the Volume Name Assigning NamesWORK1 . FIL Assigning a File Name Assigning a Point Name Assigning a Name to Coordinate Data SAMPLE1 Assigning a Name to Load DataChapter Basic Operation Basic Operating Procedure YESYesno Turning on the Main Power Cold StartingSVPMTX. SYS MCPMTX. SYS Servo Power Hot Starting Emergency Turning on the Servo Power Turn off the servo power Turning OFF the Servo PowerTurning OFF the Main Power Chapter Manual Operation Selecting the Manual Mode Save ResetEdit LoadGuidance Coordinates Guide Movement Guide Speed Guidance Servo Free Page Chapter Auxiliary Signals Procedure