ELECTRICAL
Extension Cords
Use only
**Ampere rating (on product data plate)
Cord Length |
| Wire Size (A.W.G.) |
|
| ||
|
|
|
|
|
|
|
25' | 16 | 16 | 16 | 16 | 14 | 14 |
50' | 16 | 16 | 16 | 14 | 14 | 12 |
|
|
|
|
|
|
|
100' | 16 | 16 | 14 | 12 | 10 | — |
**Used on 12 gauge - 20 amp circuit. NOTE: AWG = American Wire Gauge
When working with the product outdoors, use an extension cord that is designed for outside use. This is indicated by the letters
Before using an extension cord, inspect it for loose or exposed wires and cut or worn insulation.
WARNING:
Keep the extension cord clear of the working area. Position the cord so that it will not get caught on lumber, tools, or other obstructions while you are working with a power tool. Failure to do so can result in serious personal injury.
WARNING:
Check extension cords before each use. If damaged replace immediately. Never use the product with a damaged cord since touching the damaged area could cause electrical shock resulting in serious injury.
Electrical Connection
This product is powered by a
Grounding Instructions
This product must be grounded. In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with an electric cord having an
Do not modify the plug provided. If it will not fit the outlet, have the proper outlet installed by a qualified electrician.
WARNING:
Improper connection of the grounding plug can result in a risk of electric shock. When repair or replacement of the cord is required, do not connect the grounding wire to either flat blade terminal. The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.
Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the product is properly grounded.
Repair or replace a damaged or worn cord immediately.
This product is for use on a nominal 120 V circuit and has a grounding plug similar to the plug illustrated below. Only connect the product to an outlet having the same configuration as the plug. Do not use an adapter with this product.
Grounding
Pin
GFCI receptacle