Empire Products GWT-25-2(SG, GWT-35-2(SG Troubleshooting, Pilot Does Not Light

Page 14

TROUBLESHOOTING

GENERAL All furnaces have been fire-tested to check for proper operation. This includes main burner flame, pilot flame, and gas control operation. If the furnace fails to function on initial installation, it is advisable to re-check the following:

1.Inlet gas pressure.

2.Type of gas being used and that shown on the rating plate.

The Service Department at Empire Comfort Systems, Inc. may be contacted to assist in servicing furnace.

Servicing the Pilot and Main Burner, Pilot Orifice, Thermopile and Main Burner Orifice

Disconnect the gas supply at the inlet to the control valve. Remove the burner assembly to which the above components are attached.

Pilot Does Not Light

With air in the gas line, such as when the furnace is first installed or was "OFF" all summer, the pilot flame may be too lean to ignite on the first few trials. Turn the gas control knob to PILOT position and depress the gas control knob. Hold the gas control knob down to bleed the line;

1.Use lighter rod to light pilot with a match.

If Pilot Does Not Light By Any Means

1.Check gas control knob for being in the "Pilot" position.

2.Check pilot adjustment for being full open (counterclockwise to open).

3.If gas is available in the supply tubing, the pilot orifice and/or pilot burner is probably restricted by a spider web. Clean pilot assembly and relight.

If Pilot Does Not Remain "On" After Releasing Gas Control

Knob

1.Follow instructions and hold gas control knob down longer and harder.

2.Determine if pilot flame extends past thermopile; if not, adjust pilot flame or clean pilot burner.

3.Replace thermopile if millivolt reading is less than 300 millivolts when wall thermostat or remote bulb is turned OFF. Replace gas control if magnet dropout millivolt reading is over 100 millivolts.

Pilot Outage During Normal Operation

1.Check input by manifold pressure gauge or gas meter.

2.Check millivolt output when furnace is in operation. If millivolt output decreases during furnace operation gas control may be defective.

Main Gas Valve Does Not Open When Thermostat Is Turned "On"

1.Check millivolt output of thermopile.

2.Thermostat wires may be broken.

3.Thermostat may be defective.

Page 14

12425-10-1008

Image 14
Contents Installation Instructions Table of Contents Important Safety Information This is a Heating ApplianceSafety Information for Users of LP-GAS LP-GAS Warning OdorSpecifications IntroductionInsulated Vent Enclosure Recommended Vent ConfigurationOval all parts purchase locally GAS Supply Installing a New Main Gas CockPressure Testing of the Gas Supply System Recommended Gas Pipe DiameterLocation ALL Models ClearancesVentilation and Combustion AIR ROUGH-IN InstructionsPlastering Figure Installing Furnace FigureFinishing Instructions Installing Control Door Outer Casing FigureSystem Check Figure Recommended Wire GaugesThermostat Location SG Models Lighting Instructions What to do if YOU Smell GASProper Pilot Flame Vent Safety Shutoff SystemProper Main Burner Flame Pilot Does Not Light TroubleshootingMain Gas Valve Does Not Open When Thermostat Is Turned On If Pilot Does Not Light By Any MeansIndex Description Parts ListHOW to Order Repair Parts Parts View GWT-25 RB, GWT-35 RB, GWT-50 RB Remote Bulb Control Installation InstructionsModels InstructionsGWT-25 SG, RB, GWT-35 SG, RB, GWT-50 SG, RB Optional Blower Installation InstructionsGWTB-2 for Models Fan Control WiringParts List Service Notes Instructions Pour L’INSTALLATION Manuel DU Propriétaire Table DES Matières SectionInformation Importante DE Sécurité Ceci EST UN Appareil DE ChauffageInformation DE Sécurité Pour LES Utilisateurs DE Propane Avertissement IntroductionSpécifications Enceinte Isolée de l’Évent Configuration Recommandée Pour L’ÉVACUATIONOvale de 4 102mm toutes les pièces sont achetées localement Test de Pression du Système dAlimentation de Gaz Le Diamètre recommandé de tuyau de gazAlimentation EN GAZ Vérifier les Pressions de GazAIR DE Ventilation ET DE Combustion EMPLACEMENT- Pour Tous LES ModèlesEspaces Libres Instructions SommairesPlâtrage Figure Installer la Fournaise FigureInstructions Pour LA Finition Installer LA Porte DE Commande Paroi Extérieure FigureEmplacement DU Thermostat Modèles SG Vérification du Système FigureVeilleuse Fermé Instructions DallumageQuoi Faire SI Vous Sentez LE GAZ OuvertAspect Convenable DE LA Flamme DE LA Veilleuse LE Système DE Fermeture DE Sûreté DE L’ÉVENTEn Aucune Façon, la Veilleuse ne s’Allume Pas Détection DES DéfectuositésVeilleuse ne s’Allume pas Panne de la Veilleuse lors d’un Fonctionnement NormalFaçon DE Commander LES Pièces DE Réparation Liste DES PiècesVUE DES Pièces Modèles Instructions Pour L’INSTALLATION DE LA CommandeGWT-25-RB, GWT-35-RB, GWT-50-RB Sur un Mur Solide Sur un Mur en PlacoplâtreAvertissement Commande du VentilateurListe des Pièces HuilerPage Instrucciones DE Instalacion Manual DEL Propietario Tabla DE Contenido SecciónImportante Información DE Seguridad Este ES UN Aparato DE CalefacciónInformación DE Seguridad Para Usuarios DE GAS Propano LP Introducción EspecificacionesConfiguración Recomendada Para Ventilación Cercamienos Aislados para HumerosInstalando una Nueva Llave para Válvula Abastecimiento DE GASDiámetro Recomendado de Tubería Probando la Presión en el Sistema de GasUbicación Todo Modelo Espacios LibresVentilación Y Aire Para Combustión Instrucciones DE BosquejoInstalando el Calentador Figura Instrucciones DE AcabadoEnyesando Figura Carcasa Exterior Figura Instalando LA Puerta DE ControlInspección del Sistema Figura Instalación DEL Termostato Modelos SGGalgas Recomendadas DEL Alambre Forzar o reparar puede causar un incendio o explosión Instrucciones DE EncendidoQUÉ Hacer SI Huele GAS Flama Correcta DEL Quemador Principal Flama Correcta DEL PilotoSi el Piloto no Enciende de Ninguna Manera Apago del Piloto Durante Operación NormalÍndice Parte Descripción Lista DE PartesComo Pedir Partes DE Repuesto Vista DE Partes Instrucciones ModelosIndice Parte Descripción Sobre una Pared de Yeso Instalación del Ventilador Usando un Enchufe de Tres PuntasSobre una Pared Sólida Instalación del Ventilador con Conexión Eléctrica DirectaAdvertencia Lista DE PartesNotas DE Servicio Técnico