Empire Products GWT-25-2(SG Optional Blower Installation Instructions, GWTB-2 for Models

Page 18

OPTIONAL BLOWER INSTALLATION INSTRUCTIONS

GWTB-2 FOR MODELS

GWT-25 (SG, RB), GWT-35 (SG, RB), GWT-50 (SG, RB)

Installing Blower Using Three-Prong Plug

1.Install furnace according to Installation Instructions and Owner's Manual.

2.Refer to Drawing for measurements to locate (2) mounting holes on wall surface above furnace.

On Solid Wall

3.After locating mounting holes, attach (2) #10 x 1 1/2" screws provided in blower kit into wall. Do not completely tighten screwheads to wall,

leave a 7/16" gap between screwheads and wall.

On Sheet Rock Wall

3.After locating mounting holes, drill (2) 5/16" diameter holes into wall. Insert the (2) plastic expansion anchors into holes. Insert (2) #10 x 1 1/2" screws provided in blower kit into (2) plastic expansion anchors. Do not completely tighten screwhead to plastic expansion anchors, leave a 7/16" gap between screwheads and plastic expansion anchors. Refer to Figure 2.

4.At the top of outer casing remove (1) screw from center clearance hole that attaches outer casing to header assembly. Also, remove (2) screws that attach bottom of outer casing to inner casing.

5.Pull the outer casing forward approximately 1 inch away from wall surface.

6.Remove (4) 8 x 3/8" screws that attach blower front to blower housing.

Caution: When removing blower front be careful not to damage motor coil wires. Damaged coil wires will disable blower function.

7.Position blower housing on top of header assembly and route three- prong cord set between left side of outer casing and inner casing.

Caution: Blower cord set routing is important. Cord set should be in proper location to avoid being overheated. Incorrect routing of cord set may result in damage to cord set.

8.Replace the outer casing to the wall surface.

9.Attachoutercasingtoheaderassembly. Attention:Thecenterclearance hole will not be used. The two outside clearance holes will be used to attach outer casing to header assembly, (1) screw from Step 4 and

(1) screw supplied in hardware package. Refer to Figure 1.

Caution: When installing blower housing onto wall be careful motor coil is not damaged.

Installing Blower With Hard Wiring

1.When facing the wall opening, install 120V electrical outlet junction box inside wall opening on left wall stud approximately 12 inches above header plate.

2.Refer to Drawing for measurements to locate access hole for electrical wiring on wall surface.

3.After locating access hole, drill a 1/2" hole into wall.

4.Route enough field wiring from 120V electrical outlet junction box through 1/2" access hole in wall for connection to blower housing.

5.Install furnace according to Installation Instructions and Owner's Manual.

6.Refer to Drawing for measurements to locate (2) mounting holes on wall surface above the furnace.

On Solid Wall

7.After locating mounting holes, attach (2) #10 x 1 1/2" screws provided in blower kit into wall. Do not completely tighten screwheads to wall,

leave a 7/16" gap between screwheads and wall.

On Sheet Rock Wall

7.After locating mounting holes, drill (2) 5/16" diameter holes into wall. Insert (2) plastic expansion anchors into holes. Insert (2) #10 x 1 1/2" screws provided in blower kit into (2) plastic expansion anchors. Do not completely tighten screwhead to plastic expansion anchors, leave a 7/16" gap between screwheads and plastic expansion anchors. Refer to Figure 2.

Figure 1

10.Attach outer casing to inner casing with (2) screws from Step 4.

11.Align key hole slots on back of blower housing with the (2) screws attached to wall. Position blower housing flush with wall surface and on top of outer casing. Complete tightening blower housing screws from Step 3 to wall.

12.Attach caps and plugs from blower housing and blower front.

13.Attach blower front to blower housing with (4) 8 x 3/8" screws from Step 6.

14.Installation of optional blower assembly is completed.

Page 18

Figure 2

8.Remove three prong cord set from blower housing.

9.Remove (4) 8 x 3/8" screws that attach blower front to blower housing.

10.Position blower housing on top of header assembly.

11.Route 120V field wiring into blower housing through cord set hole on back of blower housing.

12.Refer to wiring diagram to make wiring connections inside blower housing. Be sure to follow all local and National electrical codes when making field wiring connections.

13.Align key hole slots on back of blower housing with (2) screws attached to wall. Position blower housing flush with wall surface and on top of outer casing. Complete tightening blower housing screws from Step 7 to wall.

14.Attach caps and plugs from blower housing and blower front.

15.Attach blower front to blower housing with (4) 8 x 3/8" screws from Step 9.

16.Installation of optional blower assembly is completed.

12425-10-1008

Image 18
Contents Installation Instructions Table of Contents Important Safety Information This is a Heating ApplianceSafety Information for Users of LP-GAS LP-GAS Warning OdorSpecifications IntroductionRecommended Vent Configuration Oval all parts purchase locallyInsulated Vent Enclosure GAS Supply Installing a New Main Gas CockPressure Testing of the Gas Supply System Recommended Gas Pipe DiameterLocation ALL Models ClearancesVentilation and Combustion AIR ROUGH-IN InstructionsInstalling Furnace Figure Finishing InstructionsPlastering Figure Installing Control Door Outer Casing FigureRecommended Wire Gauges Thermostat Location SG ModelsSystem Check Figure Lighting Instructions What to do if YOU Smell GASVent Safety Shutoff System Proper Main Burner FlameProper Pilot Flame Pilot Does Not Light TroubleshootingMain Gas Valve Does Not Open When Thermostat Is Turned On If Pilot Does Not Light By Any MeansParts List HOW to Order Repair PartsIndex Description Parts View GWT-25 RB, GWT-35 RB, GWT-50 RB Remote Bulb Control Installation InstructionsModels InstructionsOptional Blower Installation Instructions GWTB-2 for ModelsGWT-25 SG, RB, GWT-35 SG, RB, GWT-50 SG, RB Wiring Parts ListFan Control Service Notes Instructions Pour L’INSTALLATION Manuel DU Propriétaire Table DES Matières SectionInformation Importante DE Sécurité Ceci EST UN Appareil DE ChauffageInformation DE Sécurité Pour LES Utilisateurs DE Propane Introduction SpécificationsAvertissement Configuration Recommandée Pour L’ÉVACUATION Ovale de 4 102mm toutes les pièces sont achetées localementEnceinte Isolée de l’Évent Test de Pression du Système dAlimentation de Gaz Le Diamètre recommandé de tuyau de gazAlimentation EN GAZ Vérifier les Pressions de GazAIR DE Ventilation ET DE Combustion EMPLACEMENT- Pour Tous LES ModèlesEspaces Libres Instructions SommairesInstaller la Fournaise Figure Instructions Pour LA FinitionPlâtrage Figure Installer LA Porte DE Commande Paroi Extérieure FigureEmplacement DU Thermostat Modèles SG Vérification du Système FigureVeilleuse Fermé Instructions DallumageQuoi Faire SI Vous Sentez LE GAZ OuvertAspect Convenable DE LA Flamme DE LA Veilleuse LE Système DE Fermeture DE Sûreté DE L’ÉVENTEn Aucune Façon, la Veilleuse ne s’Allume Pas Détection DES DéfectuositésVeilleuse ne s’Allume pas Panne de la Veilleuse lors d’un Fonctionnement NormalFaçon DE Commander LES Pièces DE Réparation Liste DES PiècesVUE DES Pièces Instructions Pour L’INSTALLATION DE LA Commande GWT-25-RB, GWT-35-RB, GWT-50-RBModèles Sur un Mur Solide Sur un Mur en PlacoplâtreAvertissement Commande du VentilateurListe des Pièces HuilerPage Instrucciones DE Instalacion Manual DEL Propietario Tabla DE Contenido SecciónImportante Información DE Seguridad Este ES UN Aparato DE CalefacciónInformación DE Seguridad Para Usuarios DE GAS Propano LP Introducción EspecificacionesConfiguración Recomendada Para Ventilación Cercamienos Aislados para HumerosInstalando una Nueva Llave para Válvula Abastecimiento DE GASDiámetro Recomendado de Tubería Probando la Presión en el Sistema de GasUbicación Todo Modelo Espacios LibresVentilación Y Aire Para Combustión Instrucciones DE BosquejoInstrucciones DE Acabado Enyesando FiguraInstalando el Calentador Figura Carcasa Exterior Figura Instalando LA Puerta DE ControlInstalación DEL Termostato Modelos SG Galgas Recomendadas DEL AlambreInspección del Sistema Figura Instrucciones DE Encendido QUÉ Hacer SI Huele GASForzar o reparar puede causar un incendio o explosión Flama Correcta DEL Quemador Principal Flama Correcta DEL PilotoSi el Piloto no Enciende de Ninguna Manera Apago del Piloto Durante Operación NormalLista DE Partes Como Pedir Partes DE RepuestoÍndice Parte Descripción Vista DE Partes Modelos Indice Parte DescripciónInstrucciones Sobre una Pared de Yeso Instalación del Ventilador Usando un Enchufe de Tres PuntasSobre una Pared Sólida Instalación del Ventilador con Conexión Eléctrica DirectaAdvertencia Lista DE PartesNotas DE Servicio Técnico