10.Mark the zone number on the transmitter.
11.After the transmitter has been entered into the system, press [✱] to continue.
Typical summary display
Zn ZT – RC In: L
20 03 – 3C RF: –
Pr ogr a m Alpha ?
0 = No 1 = Ye s 0
Ente r Zn Num . |
|
(0 0 = Q uit) | 2 1 |
A summary of the programmed values for the selected zone will now be displayed
If all is okay, press [ ✱] for the next display.
Alpha descriptors for the zones can be done now, or may be done at a later time using ✱82 interactive mode (enter “0”).
Refer to ALPHA DESCRIPTOR PROGRAMMING section for performing this procedure in the ✱82 interactive menu mode.
If “0” (no) was entered in response to the Pr ogr a m Alpha ? question, a prompt will then be displayed for entry of the number for the next wireless zone to be programmed.
12.Proceed with the programming of the next wireless zone, starting at step 5 again.
13.To exit field ✱ 56 when completed, key [0 ][0] at the “Enter Zone Number” prompt.
14.Exit the programming mode by keying ✱99.
Special Notes on Zone | • | In field *56, at the summary line for each zone, the entered values can be |
Programming (5700 RF |
| checked. If you wish to change anything, press [#] to move to the previous |
Systems) |
| entry. Press [#] a number of times to move to earlier entries. Press [✱] to |
|
| move to later entries again. |
| • | Zone entries can be reviewed by pressing [#][5][6]. Changes cannot be |
|
| made here, so this is safer for review. Enter the first zone number to be |
|
| viewed and press [#]. To view each zone, press [#] and the zone number |
|
| will advance to the next programmed zone. When the end of the list is |
|
| reached, press [0][0] to exit. This method of exiting may also be done at any |
|
| time during the review. |
| • | To either temporarily or permanently remove a zone from the system, go |
|
| into programming mode and press [ ✱][5][6]. Enter the zone number and |
|
| press [ ✱]. At the Zone Type prompt, enter [0][0] and [ ✱]. This sets the type |
|
| of the zone to Not Used. The next prompt will be "Delete Zone?". "Yes" will |
|
| permanently remove the zone from the system, while "No" will disable it but |
|
| retain all data except the original zone type. You can then go back to this |
|
| zone later and put back an active Zone Type to |
Go/No Go Test Before mounting transmitters permanently, conduct Go/No Go tests to verify adequate signal strength and reorient or relocate transmitters if necessary.
During this mode, wireless receiver gain is reduced by 50%. Testing in this mode assists in determining good mounting locations for the transmitters and verifies that the RF transmission has sufficient signal amplitude margin for the installed system.
1.Enter the Installer Code + # + 4
2.Once transmitters are placed in their desired locations and the approximate length of wire to be run to sensors is connected to the transmitter's screw terminals, fault each transmitter. Do not conduct this test with your hand wrapped around the transmitter as this will cause inaccurate results.
• The keypad will beep three times to indicate signal reception.
– 30 –