Keypad Functions

General Note that if you enabled QUICK ARM (field 21), the [#] key can be pressed Information instead of entering the security code, for any of the arming procedures (Away, Stay, Instant, Maximum, etc.). The security code is always required, however,

when disarming the system.

NOTE: The “Quick Arm” feature will function only if the Master Code has been programmed (see Assigning the Master Code on the previous page).

The keypad allows the user to arm and disarm the system, and perform other system functions, such as bypassing zones, and display zone descriptors. Zone and system conditions (alarm, trouble, bypass) are displayed in the Display Window.

When an alarm occurs, keypad sounding and external sounding will occur, and the zone(s) in alarm will be displayed on the keypad. Pressing any key will silence the keypad sounder for 10 seconds. Disarming the system will silence both keypad and external sounders. When the system is disarmed, any zones that were in an alarm condition during the armed period will be displayed (memory of alarm). To clear this display, simply repeat the disarm sequence (enter the security code and press the OFF key) again.

The keypads also feature chime annunciation, and 3 panic key pairs, or individual panic keys (depending on keypad type – see Panic Keys on next page), for silent, audible, fire or personal emergency alarms. These keys can notify the central station of an alarm condition, if that service is connected.

Arming Functions The following is a brief list of system commands. For detailed information concerning system functions, refer to the User's Manual.

Disarmed, Not Ready

...........Before arming, the system must be in the

 

READY condition (all zones must be intact). If

 

the "NOT READY" message appears, press the

 

READY [] key to display faulted zones.

Arming Away

Enter code + AWAY [2].

Arming Stay

Enter code + STAY [3].

Arming Instant

Enter code + INSTANT [7].

Arming Maximum

Enter code + MAXIMUM [4].

Quick Arming

Simply press [#] key in place of code, then press

(if enabled)

AWAY, STAY, INSTANT, or MAXIMUM to arm

 

system as desired. Note that the [#] key cannot

 

be used in place of code when disarming the

 

system.

Disarming

Enter code + OFF [1].

Bypassing Zones

Enter code + BYPASS [6] + zone number(s).

Forced (Quick) Bypass

........ To automatically bypass all faulted zones, use

(if enabled)

the "Quick Bypass" method:

 

Enter code + BYPASS, then wait for all open

 

zones to be displayed. Arm when display

 

indicates “Bypass” and “Ready to Arm”.

Chime Mode

Enter code + CHIME [9].

 

To turn chime off, enter code + CHIME again.

SUMMARY OF ARMING MODES

 

 

Features for Each Arming Mode

 

Arming

Exit

 

Entry

Perimeter

Interior

Mode

Delay

 

Delay

Armed

Armed

AWAY

Yes

 

Yes

Yes

Yes

STAY

Yes

 

Yes

Yes

No

INSTANT

Yes

 

No

Yes

No

MAXIMUM

Yes

 

No

Yes

Yes