Output Relay Displays

Enter Relay No.

 

(00 = Quit)

01

02A EV ZL ZT STT 0 0 0 00

02A EV ZL ZT STP – – 0 00

Upon pressing 80, this screen will appear. Enter the Relay Number 01, 02, 03, or 04 for a 4204 (or 00 to end these entries). Press the [] key to continue.

The [] key is used to accept an entry and advance to the next prompt. The

[#]key is used to revert back to the last question to check or change an entry. Press [ ] to go forward again.

This screen displays a summary of the current Relay START programming (for this example, relay 02 has been selected).

Press the [ ] key to continue.

This screen displays a summary of the current Relay STOP programming. Press the [ ] key to continue.

 

 

 

 

 

 

02

Relay Action

 

 

 

No Response

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02

Start Event

 

 

 

Not Used

0

 

 

 

 

 

 

 

 

 

 

 

Enter the desired relay action as listed below. Press the [] key to continue.

0

= No response

2 = Close and Stay Closed

1

= Close for 2 seconds

3 = Continuous Pulse on & off ( 1 sec ON, 1 sec OFF)

Enter the event to START the relay:

0 = Not used; 2 = Fault; 1 = Alarm; 3 = Trouble

A zone list must be used in conjunction with an event. If a zone type/system operation is to be used instead of an event, enter 0.

Press the [ ] key to continue.

 

 

 

 

 

 

 

 

 

 

02 Start:

Zn List

 

 

 

 

No List

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02 Start:

Zn Typ

 

 

 

 

 

Not Used

00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

02 Stop:

Zn List

 

 

No List

0

 

 

 

 

 

 

 

 

 

 

 

 

 

02 Stop:

Zn Typ

 

 

Not Used

00

 

 

 

 

 

 

 

 

 

02A EV ZL ZT STT 0 0 0 00

02A EV ZL ZT STP – – 0 00

If a zone list will be used to START the relay action, enter the zone list number (to be programmed in field 81): 1, 2, or 3. If not used, enter 0. Press the [ ] key to continue.

If a zone type or system operation will be used to START the relay action, enter the appropriate two-digit code (see table that follows). If not, enter 00. Press the [ ] key to continue.

 

 

CHOICES FOR ZONE TYPES

 

00

= Not Used

05

= Trouble Day/Alarm Night

08 = 24 Hr Aux

01

= Entry/Exit

06

= 24 Hr Silent

09 = Fire

03

= Perimeter

07 = 24 Hr Audible

10 = Interior w/Delay

04

= Interior Follower

 

 

 

 

CHOICES FOR SYSTEM OPERATION

 

20

= Arming–Stay

33 = Any Burglary Alarm

39 = Any Fire Alarm

21

= Arming–Away

34 = Code + # + 7 Key Entry

40 = Bypassing

22

= Disarming (Code + OFF)

35 = Code + # + 8 Key Entry

41 = AC Power Failure

31

= End of Exit Time

36

= At Bell Timeout**

42 = System Batt. Low

32

= Start of Entry Time

38

= Chime

58 = Duress

 

**Or at Disarming, whichever occurs earlier.

If a zone list will be used to STOP, or restore, the relay action, enter the zone list (ZL) number 1, 2, or 3 (to be programmed in 81 mode). If not used, enter 0.

Press the [ ] key to continue.

If a zone type or system operation will be used to STOP the relay action, enter the appropriate two digit code (see the "ZT" choices listed above). If not, enter 00. Press the [] key to continue.

This screen again displays a summary of the current relay START programming.

Press the [ ] key to continue.

This screen again displays a summary of the current relay STOP programming. Press the [ ] key to continue.

– 42 –

Page 42
Image 42
VistaQuest N7227V5 installation instructions Choices for Zone Types