TO PROGRAM SYSTEM STATUS AND RESTORE REPORT CODES (✱60 – ✱68, ✱70 – ✱75)
Example 1. Pager displays: 1 2 3 4 – 9 1 1 – 0 0 4 Ê
This indicates that Subscriber No. 1234’s system is reporting an Alarm (911), due to zone 4 being faulted (004).
Example 2. Pager displays: 1 2 3 4 – 0 0 1 – 0 0 5
This indicates that Subscriber No. 1234’s system is reporting an opening (001) by User 5 (005).
Note that no restore reports are sent to the pager.
Important: Do not use AAV when Paging or Alarm Reports are being sent to a Secondary number. If this is done, the call to the Secondary number by the communicator after the alarm report will prevent the AAV from taking control of the phone line, and the AAV “Listen in” session cannot take place.
Press ✱48
Press ✱49 PERIODIC TEST REPORT
Select the desired test report interval.
0 = none; 1 = 24 hours; 2 = weekly; 3 = 30 days. Default is 0 (none). Test Report Code entered in field ✱ 64 is sent. Reports with Subscriber No.
Press ✱50 SESCOA/RADIONICS SELECT 0 = Radionics
Select 0 for all other formats. Default is 0.
With a 3+1 or 4+1 Standard Format: Enter a code in the first digit box:
A "0" (not "# + 10") in the first digit box will disable a report.
A "0" ( not "# + 10") in the second digit box (if any) will result in automatic advance to the next field when programming.
With an Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for
A "0" (not "# + 10") in the second box will eliminate the expanded message for that report.
A "0" (not "# + 10") in both boxes will disable the report.
With Ademco Contact ID Reporting: Enter any digit (other than "0") in the first box, to enable zone to report This is an "enabling" code only and is disregarded in the actual reporting to the central office. Entries in the second boxes will be ignored.
A "0" (not "# + 10") in the first box will disable the report.
Examples: |
|
|
|
For Code 3 (Single Digit), enter: | 3 |
| 0 |
For Code 32 (Two Digits), enter: |
|
| |
3 |
| 2 | |
For Code B2 (Hexadecimal) enter: |
|
| |
# + 11 |
| 2 |
Press ✱60 TROUBLE REPORT CODE
This will be sent if a zone goes into trouble.
Press ✱61 BYPASS REPORT CODE
This will be sent when a zone is manually bypassed.
Press ✱62 AC LOSS REPORT CODE
Reports with Subscriber No. Timing of this report is random with up to a
– 68 –