Optional Output Relays • Up to 4 relays using one 4204 Relay Module.
• Actions programmable to respond to zone activity or manual keypad entries.
Optional Phone module • Supports the Ademco 4285 Phone module .
•Provides access to the system via on premises or
Optional Long Range • Allows all messages that have been programmed to go to the primary
Radio telephone number to be reported additionally to a 7720 PLUS or 7820 radio.
Alarm Output • Provides a 12VDC, 2 AMP output that can drive the compatible sounders listed in the EXTERNAL SOUNDERS section (assumes a fully charged battery is connected).
•Steady output for Burglary/Panic, or temporal pulse sounding output for Fire notification, as required by UL.
•Uses current limiting circuitry for protection.
Auxiliary Power Output • Provides 12VDC, 500mA maximum. Uses current limiting circuitry for protection.
•This output interrupts for smoke detector reset if
Programming • Programmed options are stored in electrically erasable,
•The system can be uploaded, downloaded, or controlled via an IBM compatible computer, using either Ademco’s
Keypad programming consists of:
•Data field programming.
•Interactive (menu) mode programming.
For programming from a keypad, a 5137AD or 6139
Communication Formats | • Ademco Low Speed (Standard or Expanded). |
Supported | • Sescoa/Radionics (Standard or Expanded). |
| |
| • Ademco Express. |
| • Ademco Contact ID. |
Zone Descriptors | You can assign Alpha descriptors to all zones (useful only when using Alpha |
| keypads and/or the 4285 Phone module). |
AC Power Supply | Uses No. 1321, 120VAC |
| (1321CN in Canada) |
| • Rechargeable (Gel type) 12VDC, 4AH minimum. |