Section 8. EXTERNAL SOUNDERS

This section provides a list of compatible sounders, connection information for an external sounder and programming procedures for those options that affect the operation of external sounders .

Compatible Sounders

Ademco AB-12M 10”

Motor bell & box. UL Grade A. 100mA current

Motorized Bell & Box

draw.

 

Ademco 1011BE12M

Motor bell & box. UL Listed. 100mA current draw.

10” Motorized Bell &

 

 

Box

 

 

Ademco 702

Self-contained 6–12 volt siren (driver built-in) and

Outdoor Siren

weatherproof for outdoor use. Can be wired for

 

either a steady or warble sound. 117dB @ 10

 

feet. 1500mA current draw.

Ademco 719

Self-contained 6–12-volt siren (driver built in).

2-Channel Siren

Steady or warble sound. 109dB @ 10 feet.

 

550mA current draw.

 

Ademco 747

Self-contained 6–15 volt siren (driver built-in) for

Indoor Siren

indoor wall mount.

747F available for flush

 

mounting. 105dB @ 10 feet. 400mA current draw.

 

 

Ademco 747UL

Self-contained 6–15 volt siren (driver built-in) for

Indoor Siren

indoor wall mount.

UL Listed. 85dB @ 10 feet.

 

320mA current draw.

 

Ademco 744

6 jumper-selected sound outputs. Rated at 119dB

Siren Driver

with use of an 8-ohm 30 watt speaker. 1.3 amps

 

current draw.

 

Ademco 745X3*

12 volt voice siren driver with English, Spanish

Voice Siren Driver

and French voice messages. Separate messages

 

for Fire and Burglary. Use with 8-ohm speaker.

 

UL Listed. 1100mA current draw.

Ademco 705–820,

20-watt, 8-ohm indoor or outdoor speaker.

5-inch Round Speaker

Requires a driver.

 

Ademco 713 Speaker

40-watt, 8-ohm, indoor/outdoor speaker. Requires

 

a driver.

 

System Sensor PA400B

Indoor piezo sounder (red or beige), rated at 90

(beige)/PA400R (red)

dB @ 10 feet.

 

Indoor Piezo Sounder

 

 

*Requires special power wiring, using additional components.

UL

Use only UL Listed sounding devices for UL installations.

The total current drawn from the alarm output and the auxiliary power output, combined, cannot exceed 600mA. In addition, the sounding device must be a UL Listed audible signal appliance rated to operate in a 10.2-13.8 VDC voltage range, and must be mounted indoors. Example: Wheelock Signals Inc. siren model 34T-12 (provides 85dB[A] for NFPA 74 & Standard 985).

Non-UL Installations

The total current drawn from the alarm output terminals cannot exceed 2 amps. The back-up battery must be installed since this current is supplied by that battery.

Going beyond the limits indicated (2 amps) will overload the power supply, or may cause the electronic circuit protecting the sounder output to trip.

– 49 –

Page 49
Image 49
VistaQuest N7227V5 installation instructions External Sounders