10 Input S/N:

L

 

 

The system will enroll the serial number of the first transmitter heard,

 

 

 

 

 

add the loop number entered to this serial number, display the serial

 

 

 

A002-4064

1

 

 

 

 

 

 

 

and loop numbers, and cause the keypad to beep twice.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If the serial and loop number combination is already present in the

 

 

 

 

 

 

 

 

system, a single long beep will be heard from the keypad. If this happens,

 

 

 

 

 

 

 

 

the system will not display the serial number, but will wait for a

 

 

 

 

 

 

 

 

transmission from another transmitter or transmitter loop input.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12. The system will then enter an optional confirmation mode so that the

 

 

 

 

 

 

 

 

operation of the actual programmed input can be confirmed. Activate

 

 

 

 

 

 

 

 

the loop input or button that corresponds to this zone. We

 

 

 

 

 

 

 

 

recommend that you confirm the programming of every

 

 

 

 

 

 

 

 

transmitter before proceeding to the next zone.

 

 

 

 

 

 

 

 

When the system sees activity on the appropriate input, it will beep

 

 

 

10 Confirmed

 

 

 

 

 

 

 

 

 

three times and display the confirmation message.

 

 

 

A022– 4064

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

At any time during this step, you may press the [] key on the keypad or

 

 

 

 

 

 

 

the upper left-hand button of the program tool if you are satisfied with the

 

 

 

 

 

 

 

serial and loop number combination that has been enrolled, regardless of

 

 

 

 

 

 

 

whether or not the enrolled input has been "confirmed."

 

 

 

 

 

 

 

If the incorrect transmitter has been enrolled, press the # key on the

 

 

 

 

 

 

 

keypad or the upper right-hand button of the program tool to delete the

 

 

 

 

 

 

 

serial number and return to the "Learn S/N" prompt. A single long beep will

 

 

 

 

 

 

 

be heard from the keypad to verify pressing of the upper right-hand button.

 

 

 

 

 

 

 

Then, press "1" (Yes) or press the upper left-hand button of the program

 

 

 

 

 

 

 

tool (a single short beep will verify the system is ready for enrolling) and

 

 

 

 

 

 

 

re-activate the proper transmitter or transmitter loop input.

 

 

 

 

 

 

13.

The summary screen for the zone will appear. Note that an "s"

 

 

 

ZN ZT – RC IN:

L

 

 

 

 

 

indicates that a serial number has, in fact, been enrolled. The cursor

 

 

 

10 03 – 00 RF: 1 s

 

 

 

 

 

 

 

will be flashing above the loop number. Press [] to accept the zone

 

 

 

 

 

 

 

 

information.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: If you entered “0” in step 10 previously, you will not get an

 

 

 

 

 

 

 

 

indication that the serial number has been enrolled.

 

 

 

 

 

 

 

 

If you want to delete the serial number, enter "0" and press [ ]. The

 

 

 

 

 

 

 

 

system will then prompt, "Delete S/N?" Press the "1" (Yes) key to

 

 

 

 

 

 

 

 

complete the delete sequence. This process deletes the serial number

 

 

 

 

 

 

 

 

only, not the loop number. The assumption is that the proper loop

 

 

 

 

 

 

 

 

number was programmed, but the wrong serial or loop number was

 

 

 

 

 

 

 

 

enrolled. To change the loop number, you must go back through zone

 

 

 

 

 

 

 

 

programming for that zone and manually enter the loop number over

 

 

 

 

 

 

 

 

the existing one.

 

 

 

 

 

 

14.

If you want to program alpha descriptors now, enter "1" (Yes). See the

 

 

 

Program Alpha?

 

 

 

 

 

 

 

ALPHA DESCRIPTOR PROGRAMMING section for more information.

 

 

 

0 = NO 1 = YES 0

 

 

 

 

 

 

 

If not, enter "0" (No).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This will bring you back to the “Enter Zn Num.” prompt for the next

 

 

 

Ente r Zn Num .

 

 

 

 

 

 

 

zone . When all zones have been programmed, enter “00” to quit.

 

 

 

(0 0 = Q UIT)

1 1

 

 

 

 

 

 

 

If you plan to enroll serial numbers in the sequential enrollment mode,

 

 

 

 

 

 

 

 

enter “00” to quit, then go toSection 13. SEQUENTIAL MODE section

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

later in this manual to enroll the serial numbers.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

When you have finished programming all zones (including all serial

 

 

 

 

 

 

 

 

numbers), test each zone using the system's TEST mode. Do not use the

 

 

 

 

 

 

 

 

Transmitter ID Sniffer mode for this, as it will only check for transmission

 

 

 

 

 

 

 

 

of one zone on a particular transmitter, and NOT the zones assigned to

 

 

 

 

 

 

 

 

each additional loop.

 

– 36 –

Page 36
Image 36
VistaQuest N7227V5 Recommend that you confirm the programming of every, Transmitter before proceeding to the next zone