The display then returns again to the first screen so that the next relay number to be programmed can be entered, or enter [0][0] to end relay programming.
Previously entered data can be reviewed by pressing [#] [8] [0]. After the relay number is chosen, press [✱] to go to the next screens. This is a review mode only, and data cannot be changed.
Example of Output Relay Programming
Zone List Displays ↓
|
|
|
|
|
| Zone List No. |
|
| |
| (00 = Quit) | 01 |
| |
|
|
|
| |
|
|
|
|
|
|
| |||
| 01 | Enter Zn Num. |
| |
| (00 = Quit) | 00 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 01 | Del Zn List? |
|
|
| 0 = No 1 = Yes | 0 |
| |
|
|
|
| |
|
|
|
|
|
|
|
|
| |
| 01 Delete Zone? |
|
| |
| 0 = No 1 = Yes | 0 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 01 | Zn to Delete? |
|
|
| (00 = Quit) | 00 |
| |
|
|
|
|
|
|
|
|
|
|
A lamp is to be turned on when any one of 3 specific zones are faulted or when any
In field *80 we choose Output Relay 01 and program the Action (A) to be "2" (Close and stay closed). The Event we are looking for to start the relay action is a fault, so we will program "2" in (EV). We will use Zone List 1 for the 3 specific zones, so will program "1" in (ZL), (and will program these 3 zones in field *81's Zone List 1).
The second condition for turning on the indicator is triggering a 24 hour aux. zone (Zone Type 08), so we will program (ZT) as "08".
To stop relay action and turn off the indicator, we do not want to use a restore of any zone, so we will program a "0" for the " Restore of" Zone List (ZL). To choose a manual entry of User Code + [#] + [7] to turn it off, we will program (ZT) as "34".
If no other relay is to be programmed we go to field *81 and program the 3 specific zones in Zone List 1.
Press ✱81. (Zone Lists for Output Relays). This interactive mode is applicable only if you have programmed ✱80 mode.
Refer to the Programming Form worksheet for ✱81 Mode.
Upon keying ✱81, this screen will appear. Enter the Zone List Number 01, 02, or 03 to program (or 00 to end these entries). Press the [✱] key to advance.
In the following displays, zone list 01 has been selected for programming.
Enter each zone number to add to the zone list by first entering the zone number, then the [✱] key (example, 01 ✱, 02 ✱, 03 ✱). After all zones desired are entered, press 00 to advance.
To delete the zone list, enter 1 (Yes). All zones in the zone list will be deleted automatically. and programming will return to the first screen.
To save the zone list, enter 0 (No) to advance.
To delete a zone or zones in a zone list enter 1 (Yes) to advance.
Enter each zone to be deleted from the list, followed by the [✱] key. After all zones to be deleted are entered, enter 00 to return to the first screen so that another list can be programmed, if desired.
Notes:
•Any list may include any or all of the system's zone numbers.
•A zone list can be assigned to more than one output relay.
•If you only want to review what has been programmed previously, enter [#][8][1]. The review can be advanced by using the [✱] key. When finished, enter [0][0] ✱ to quit. No programmed values can be changed in this mode.
When programming in ✱80 and ✱81 interactive modes is completed, exit the programming mode by keying ✱99.