To Either Temporarily Or Permanently Remove A Zone From The System (5800 System).
1. Enter the programming mode:
Key Installer Code + 8 + 0 and press [✱][5][6].
2. Enter the zone number and press [ ✱]. A summary display will appear.
3. Press [✱] again.
2 0 Zone Type |
|
Not Use d | 0 0 |
4.The “Zone Type ” prompt will appear. Enter [0][0]. This sets the zone type to “Not Used”.
Press [✱] to continue.
| 2 0 De le te Zone ? |
| 5. The next prompt will ask whether you want to |
|
| delete the zone. | |
| 1 = Ye s 0 = No |
| |
|
| "Yes" will permanently remove the zone from | |
|
|
| the system, while a "No" will disable it but retain |
|
|
| |
|
|
|
all data except the original zone type. You can then go back to this zone later and put back an active zone type to
A serial number that has been entered for a 5800 system will not be deleted if the zone is temporarily disabled by answering “No” to the prompt above.
If only the physical transmitter is to be removed or changed (i.e., its serial number deleted, as when replacing a unit that has a
Deleting a Transmitter Serial Number From a Zone in ✱56 Mode (5800 System)
The abbreviated procedure below can be used to delete a serial number from a zone, using the ✱56 Mode.
1.In the programming mode, press [✱ ][5][6] to enter Zone Programming mode.
2.Then enter the zone number, and press [ ✱] repeatedly until the cursor is under the RF Input Loop (L) position. This is the specific input (loop) or button on the transmitter that has been entered for that zone.
3.Enter a [0] at this point, then press [✱].
4.A prompt " Delete S/N?" will appear.
Enter "Yes" to delete the existing serial number from the system.
Note that the other programmed values for that zone will not be deleted. This will allow you to
5.A display for the next zone number will appear. To exit, enter “00".
6.Press ✱99 to exit the programming mode.
Check-Out Procedure for Wireless Zones
Transmitter ID | When all transmitters have been installed, use the Transmitter Sniffer Mode to | |
Sniffer Mode | test that they have all been properly programmed. | |
(5700/5800 | 1. Enter Installer Code + # + 3. The keypad will display all zone numbers of | |
RF Systems) | ||
wireless units programmed into the system. | ||
|
2.Fault each wireless zone, causing each device to transmit. As the system receives a signal from each of the transmitters, the zone number of that transmitter will disappear from the display.
If a 5700 transmitter is not dipswitched correctly, or if a 5800 transmitter is not enrolled, its zone number will not turn off.
3.To exit the Transmitter Sniffer mode, enter the Installer Code + (OFF).
(Continued)