Zone Types

00

= Zone Not Used

08

= 24 Hr Aux

01

= Entry/Exit #1

09 = Fire

02

= not used

10 = Interior w/Delay

03

= Perimeter

20

= Arm Stay*

04

= Interior Follower

21

= Arm-Away*

05

= Trouble Day/Alarm Night

22

= Disarm*

06

= 24 Hr Silent

23

= No Alarm

 

Response

07

= 24 Hr Audible

 

 

 

* 5800 RF Systems only

When the display shows the zone type you want, press [ ] to continue.

You must enter “00”as the zone type for any hard-wired zones that are not used.

02 Report Code

1st 03 2nd 12

3C

The report code consists of 2 hexadecimal digits, each in turn consisting of 2 numerical digits. For example, for a report code of "3C", enter [0][3] for "3" and [1][2] for "C". Refer to the SYSTEM COMMUNICATION section f o r complete information on report codes, if necessary.

Enter the desired report code and then press [ ] to continue.

Typical summary display

 

 

 

 

 

 

 

 

Zn

ZT

RC

In L

 

 

02

03

3C

HW: –

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Program Alpha?

 

 

 

0 = No

1 = Yes

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A summary display will appear, showing the data for the zone that was just programmed.

If it is programmed satisfactorily, press [] to continue.

The next request is to enter Alpha descriptors for the zones. The entry may be done now (enter 1), or may be done at a later time using 82 interactive mode (enter 0). See the ALPHA DESCRIPTOR PROGRAMMING section for specific procedure.

Enter Zn Num.

(00 = Quit)

03

Enter next zone number

If “0” (no) was entered above, the system will return to the Enter Zone Number prompt. Proceed with the programming for the next zone, i.e., [ ] and zone number.

Programming Panic Keys When programming zones, note the following:

The defaults for individual panic keys or panic key pairs are: Zone 07. & #, or B: zone type 06 (24-hr silent).

Zone 95. 1 & , or A: zone type 00 (not used).

Zone 96. 3 & #, or C: zone type 00 (not used).

Panic keys are programmed (or re-programmed) by keying the zone number, e.g., 07, 95, and 96, and entering the desired zone type that will provide the desired panic function for each of these keys, using the list of zone types below.

06 = 24 Hr Silent

07 = 24 Hr Audible

08 = 24 Hr Aux

09 = Fire

– 20 –