INTRODUCTION

Introduction

Vented wall furnace is shipped ready to install in a 2" x 4" stud wall, with studs 16" (406mm) center to center. Always consult your local Building Department regarding regulations, codes or ordinances which apply to the installation of a vented wall furnace.

Instructions to Installer

1.Installer must leave instruction manual with owner after instal- lation.

2.Installer must have owner fill out and mail warranty card sup- plied with furnace.

3.Installer should show owner how to start and operate furnace and thermostat.

Warning:

Any change to this furnace or its control can be dangerous. This is a heating appliance and any panel, door or guard removed for servicing an appliance must be replaced prior to operating the appliance.

General Information

This series is design certified in accordance withAmerican National Standard / CSA Standard Z21.86 and CSA 2.32 by the Canadian Standards Association, as a Vented Wall Furnace and must be installed according to these instructions.

Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and com- pany making the change.

Important

All correspondence should refer to complete Model No., Serial No. and type of gas.

Notice: During initial firing of this furnace, its paint will bake out and smoke will occur. To prevent triggering of smoke alarms, ventilate the room in which the furnace is installed.

Installation in Residential Garages

Gas utilization equipment in residential garages shall be installed so that all burners and burner ignition devices are located not less than 18" (457mm) above the floor.

Such equipment shall be located, or protected, so it is not subject to physical damage by a moving vehicle.

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation or company which either in person or through a representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction.

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

The installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA 54* Natural Gas and Propane Installation Code, CSA B149.1.

*Available from the American National Standards Institute, Inc., 11 West 42nd St., New York, N.Y. 10036.

High Altitudes

For altitudes/elevations above 2,000 feet (610m), input ratings should be reduced at the rate of 4 percent for each 1,000 (305m) feet above sea level. Canadian HighAltitudes for locations having an elevation above mean sea level between 2,000 feet (610m) and 4,500 feet (1370m), the manifold pressure is to be decreased from 3.5" w.c. (.871kPa) to 3.0" w.c. (.747kPa) for Natural Gas and from 10.0" w.c. (2.49kPa) to 8.0" w.c. (1.992kPa) for Propane Gas.

SPECIFICATIONS

Model

GWT-25

GWT-35

Input BTU/HR (KW/H)

25,000 (7.3)

35,000 (10.3)

Height

66 1/8" (1679mm)

66 1/8" (1679mm)

Width

16" (406mm)

16" (406mm)

Depth

6" (152mm)

6" (152mm)

Gas Inlet Pipe

1/2"

1/2"

Vent Pipe Type B Oval

4" (102mm)

4" (102mm)

Accessories

 

 

Blower Kit

GWTB-2

GWTB-2

Rear Register Kit

GWTR-1

GWTR-1

Out-of-the-Wall Kit

GWTW-2

GWTW-2

Attention: When the GWTW-2, Out-of-the-Wall kit is used the GWTR-1 Rear Register kit cannot be used.

12425-10-1008

Page 5

Image 5
Contents Installation Instructions Table of Contents This is a Heating Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction SpecificationsInsulated Vent Enclosure Recommended Vent ConfigurationOval all parts purchase locally Pressure Testing of the Gas Supply System Installing a New Main Gas CockGAS Supply Recommended Gas Pipe DiameterVentilation and Combustion AIR ClearancesLocation ALL Models ROUGH-IN InstructionsPlastering Figure Installing Furnace FigureFinishing Instructions Outer Casing Figure Installing Control DoorSystem Check Figure Recommended Wire GaugesThermostat Location SG Models What to do if YOU Smell GAS Lighting InstructionsProper Pilot Flame Vent Safety Shutoff SystemProper Main Burner Flame Main Gas Valve Does Not Open When Thermostat Is Turned On TroubleshootingPilot Does Not Light If Pilot Does Not Light By Any MeansIndex Description Parts ListHOW to Order Repair Parts Parts View Models Remote Bulb Control Installation InstructionsGWT-25 RB, GWT-35 RB, GWT-50 RB InstructionsGWT-25 SG, RB, GWT-35 SG, RB, GWT-50 SG, RB Optional Blower Installation InstructionsGWTB-2 for Models Fan Control WiringParts List Service Notes Instructions Pour L’INSTALLATION Manuel DU Propriétaire Section Table DES MatièresCeci EST UN Appareil DE Chauffage Information Importante DE SécuritéInformation DE Sécurité Pour LES Utilisateurs DE Propane Avertissement IntroductionSpécifications Enceinte Isolée de l’Évent Configuration Recommandée Pour L’ÉVACUATIONOvale de 4 102mm toutes les pièces sont achetées localement Alimentation EN GAZ Le Diamètre recommandé de tuyau de gazTest de Pression du Système dAlimentation de Gaz Vérifier les Pressions de GazEspaces Libres EMPLACEMENT- Pour Tous LES ModèlesAIR DE Ventilation ET DE Combustion Instructions SommairesPlâtrage Figure Installer la Fournaise FigureInstructions Pour LA Finition Paroi Extérieure Figure Installer LA Porte DE CommandeVérification du Système Figure Emplacement DU Thermostat Modèles SGQuoi Faire SI Vous Sentez LE GAZ Instructions DallumageVeilleuse Fermé OuvertLE Système DE Fermeture DE Sûreté DE L’ÉVENT Aspect Convenable DE LA Flamme DE LA VeilleuseVeilleuse ne s’Allume pas Détection DES DéfectuositésEn Aucune Façon, la Veilleuse ne s’Allume Pas Panne de la Veilleuse lors d’un Fonctionnement NormalListe DES Pièces Façon DE Commander LES Pièces DE RéparationVUE DES Pièces Modèles Instructions Pour L’INSTALLATION DE LA CommandeGWT-25-RB, GWT-35-RB, GWT-50-RB Sur un Mur en Placoplâtre Sur un Mur SolideListe des Pièces Commande du VentilateurAvertissement HuilerPage Instrucciones DE Instalacion Manual DEL Propietario Sección Tabla DE ContenidoEste ES UN Aparato DE Calefacción Importante Información DE SeguridadInformación DE Seguridad Para Usuarios DE GAS Propano LP Especificaciones IntroducciónCercamienos Aislados para Humeros Configuración Recomendada Para VentilaciónDiámetro Recomendado de Tubería Abastecimiento DE GASInstalando una Nueva Llave para Válvula Probando la Presión en el Sistema de GasVentilación Y Aire Para Combustión Espacios LibresUbicación Todo Modelo Instrucciones DE BosquejoInstalando el Calentador Figura Instrucciones DE AcabadoEnyesando Figura Instalando LA Puerta DE Control Carcasa Exterior FiguraInspección del Sistema Figura Instalación DEL Termostato Modelos SGGalgas Recomendadas DEL Alambre Forzar o reparar puede causar un incendio o explosión Instrucciones DE EncendidoQUÉ Hacer SI Huele GAS Flama Correcta DEL Piloto Flama Correcta DEL Quemador PrincipalApago del Piloto Durante Operación Normal Si el Piloto no Enciende de Ninguna ManeraÍndice Parte Descripción Lista DE PartesComo Pedir Partes DE Repuesto Vista DE Partes Instrucciones ModelosIndice Parte Descripción Sobre una Pared Sólida Instalación del Ventilador Usando un Enchufe de Tres PuntasSobre una Pared de Yeso Instalación del Ventilador con Conexión Eléctrica DirectaLista DE Partes AdvertenciaNotas DE Servicio Técnico