Installation site selection - Indoor unit
AVOID
•Direct sunlight.
•Nearby heat sources that may affect unit performance.
•Areas where leakage of flammable gas may be expected.
•Locations where large amounts of oil mist may occur (such as in kitchen or near factory equipment) because oil contamination can cause operation problems and may deform plastic surfaces and parts of the unit.
•Unsteady locations that will cause noise or possible water leakage.
•Locations where the remote control unit will be splashed with water or affected by dampness or humidity.
•To make holes in areas where electrical wiring or conduits are located.
DO
•Select an appropriate position from which every corner of the room can be uniformily cooled.
•Select a sufficiently strong location to support the weight of the unit.
•Select a location where tubing and drain hose have the shortest run to the outside.
•Allow access for operation and maintenance as well as unrestricted air flow around the unit.
Installation site selection - Outdoor unit |
|
AVOID |
|
• Heat sources, exhaust fans. | EG |
•Direct sunlight.
•Damp, humid or uneven locations.
•To make holes in areas where electrical wiring or conduits are located.
DO
•Choose places as cool as possible and well ventilated.
•use lug bolts or equal to bolt down the unit, reducing vibration and noise.
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
●Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with foamed polyethylene (min. thickness 8mm).
MODEL | NARROW TUBE | LARGE TUBE | |||
OUTER DIAMETER | MIN. THICKNESS | OUTER DIAMETER | MIN. THICKNESS | ||
| |||||
UR9X - UR12X | 6,35 mm | 0,8 mm | 9,52 mm | 0,8 mm | |
UR18X | 6,35 mm | 0,8 mm | 12,7 mm | 0,8 mm | |
UR22X | 6,35 mm | 0,8 mm | 15,88 mm | 1 mm |
●PVC pipe for condensate drain pipe (ø int.18mm) in lenght suitable to let the condensate flow into the outside drainage.
●
●Electric wire: use insulated copper wires of size and length as shown in the table “ELECTRICAL DATA” and at paragraph “SYSTEM WIRING DIAGRAMS”.
ELECTRICAL DATA
LENGTH, WIRE SIZE AND DELAYED FUSE
MODEL | Power supply wiring length | mm2 | Power line length | mm2 | Control line length | mm2 | Delayed fuse | |
| (A) m |
| (B) m |
| (C) m |
|
| |
CR9X | 80 | 2 | 80 | 2 | 160 | 0,75 | 10 A | |
140 | 3,5 | 140 | 3,5 | |||||
|
|
|
| |||||
CR12X | 50 | 2 | 50 | 2 | 160 | 0,75 | 10 A | |
90 | 3,5 | 90 | 3,5 | |||||
|
|
|
| |||||
CR/CLR18X | 22 | 2,5 | 30 | 2,5 | 30 | 2,5 | 20 A | |
CR22X | 16 | 2,5 | 30 | 2,5 | 30 | 2,5 | 20 A |
TUBING LENGTH AND ELEVATION DIFFERENCE LIMITS
MODEL | MAX. ALLOWABLE | LIMIT OF TUBING | LIMIT OF ELEVATION | REQUIRED AMOUNT OF |
TUBING LENGTH AT | LENGTH | DIFFERENCE | ADDITIOONAL | |
| SHIPMENT | (m) | H | REFRIGERANT |
| (m) | (m) | (g / m)* | |
UR9X | 7,5 | 15 | 7 | 15 |
|
|
|
|
|
UR12X | 7,5 | 20 | 7 | 25 |
|
|
|
|
|
UR18X - 22X | 7,5 | 30 | 7 | 25 |
|
|
|
|
|
|
|
|
|
|
* For every meter of tube more than standard lenght at shipment, add refrigerant as shown in the table. No additional charge of compressor oil is necessary.
3