Operation 15
Ice CubeThickness Adjustment
Interval - As Required
Ice thickness adjustments are made using the control panel as follows:
LIGHT,
UPDOWN BLACKOUT MODE
POWER ARROW DISPLAY ARROW & OTHER FUNCTIONS
ICE
Figure 27
1.To enter the thickness adjustment mode:
a.Touch and hold the UP ARROW button.
b.Touch and release the DOWN ARROW button three times, then release the UP ARROW button.
c.The display will switch to “0,” to confirm the thickness adjustment mode has been selected.
2.The factory setting is “0,” and the total range of adjustment is
IMPORTANT
Ice thickness adjustment should only be made one increment at a time. Allow ice maker production to stabilize for 24 hours before rechecking ice thickness.
3.Touch and release the LIGHT button key to exit the ice thickness adjustment mode.
4.Remove all ice from the storage bin.
5.Ice cubes in any given batch will vary, so it is necessary to choose cubes from the sample area (Figure 28) for comparison when making adjustments. If further adjustments are desired, repeat steps 1 through 4.
SAMPLE AREA |
Figure 28 |
IMPORTANT
It is extremely important that Clear Ice models are level. If not level, the ice mold will not fill evenly.