3M XT-1, G5 operating instructions Greeter Setup Example Settings

Page 74

Appendix: Greeter Module

Greeter Setup (Example Settings)

 

Message Assignments

 

 

 

Msg #

Name

Type

Dayparts

1

Daily Promo

GREETER

10

2

------------

GREETER

10

3

Store Closed

CLOSED

 

4

------------

CLOSED

 

11

Travel Path

REMINDER

10

12

Hand Washing

REMINDER

10

16

Back Door Open

ALERT

10

Alert & Reminder Properties

Msg #

Name

Type

Priority

Delay

Count

Repeat

Monitor

11

Travel Path

REMINDER

Y

0:00

1

0:30:00

ON/OFF

12

Hand Wash

REMINDER

Y

0:00

1

1:00:00

ON/OFF

16

Door Open

ALERT

N

0:00

1

0:01:00

ON/OFF

November 6 2014 – Revision 2.1

3M™ Drive-Thru Systems Model G5 and Model XT-1

Page 74 of 77

Operating Instructions

Image 74
Contents Operating Instructions 3M Commercial Solutions Division Table of Contents Assembling a 3M Drive Thru Headset G5 Maintenance Alert Message External Trigger Inputs IndexSafety Information OverviewImportant Note Other ConventionsImportant Notes and Notes FCC and Industry Canada InformationFCC Note FCC and IC IdentifiersRecycling / Disposal Notice to European Union customers Navigating the Base Station Display ConfigurationEnter Configuration Mode Interpreting Display Information ButtonsConfiguring with a Computer ∙ Cycle the power to the base station Logging into the Base Station with a PCOutbound Talk Volume Change Basic Volume SettingsInbound Microphone Volume Vehicle Alert VolumeOutbound Talk Change the Monitor VolumeInbound Listen Vehicle PresentMessages Change the Night VolumeVehicle Approach Greeter MessagesRemove Headsets Registering HeadsetsAdd Headsets Change Noise Reduction Level List All HeadsetsResetting Inactive Days Checking Headset Software RevisionDrive Thru Audio Duplex Mode Change Global SettingsAcoustic Echo Canceller Set System Date and TimeStore is Now Closed Prompt Channel Heard by Order TakerNumber of Base Stations at this Site Pull Ahead Prompt Customer Order Point Prompt LanguageDetector Type Order Takers and Page Messages in Cross Lane ModeOrder Point Talk with No Vehicle Kitchen Noise Reduction Important NotesHaptics Vibration Alerts on Headsets Order Taking Modes SetupXT-1 Basestation Software Update Kit XT-1 Blue LED Alerts on HeadsetsHoliday/Exception Schedule Change Site SchedulingRegular Site Schedule Change Passcodes Change Site InformationChange Self Monitoring User PasscodesLoad Installation Settings Two Base Station SetupInstaller Setup Save Installation SettingsActivate the Backup Intercom Factory Setup Restore Factory DefaultsReboot System Create and Load TemplatesPage Operation 3M Drive Thru Headset G5November 6 2014 Revision Operation 3M Drive-Thru Systems Model G5 and Model XT-1 Component Identification and Description ∙ T1 and T2 Talkbuttons Connect you to the order pointIndicator Light Modes G5 Battery Indicator Light ModesG5 Headset Indicator Light Modes Fitting the Headset Replace the Battery Out of Range XT-1 HeadsetsCleaning Component Identification and Description Headset Replace the Battery Out of Range Change Order Taking Mode Base Station SetupNavigating in the Base Station in Run Mode Talk Manual Latching, Push to Talk, Automatic Explanation of Order Taking ModesListen Auto, Manual, and Always On Split Lane Which Order Taking Mode to SelectChange Lane Mode Change Volume Mode Cross LaneReplacing the Carrier MaintenanceG5 Headset Disassembling the Carrier from the PodReplacing the Ear and Headband Pads G5 Headset ChargerRefitting the headset with the new Carrier LocationG5 Batteries Cleaning the Contacts in the Headset Charger wellsLow Battery Message Care, Handling and StorageImportant Information about Rechargeable Batteries Disposing of BatteriesMaking Sure Batteries are Ready for Use XT-1 Headset XT-1 Battery ChargerCleaning the Contacts XT-1 BatteriesCharging Status Indicator Important Information about Rechargeable Batteries Troubleshooting Headset Indicator LightsG5 Headset Indicator Light Modes General Troubleshooting Problem Possible Cause SolutionPress the other button into the correct Battery and Battery Charger Troubleshooting XT-1 Battery and Battery ChargerAppendix Declaration of Conformity Electrical Appendix Base Station SpecificationsPhysical FunctionalAppendix G5 Charger Specifications Appendix Greeter Module Greeter SetupEnter the Greeter Configuration Menu Message Activation Record MessageNameBreakfast Service=Start Choose Headsets Messages Playback ToGreeter Message Properties Change Playback Delay TimeMessage Daypart Definitions Turn on Tone to Headsets During Greeter Playback Change Playback ModeSet Greeter Playback through Headsets Set Playback through MonitorGreeter Revision Turn on Restaurant Closed Playback MessageTurn on External Detector Playback Message Alert & Reminder Message Properties Alert & Reminder Message PropertiesMessage Names Dual Lane Systems LaneTandem Pull Ahead Playback Message Start Time Greeter Setup System DefaultsDelay Count Greeter Setup Customer Settings Alert & Reminder PropertiesGreeter Setup Example Settings Index 66, 67, 68, 69Talk 3M, Thinsulate, Tufcote and ScotchBrite are trademarks of 3M
Related manuals
Manual 8 pages 46.54 Kb

G5, XT-1 specifications

The 3M G5 XT-1 is a cutting-edge respirator designed for professionals who require advanced protection in various hazardous environments. With its innovative features, this respirator stands out in the market, providing users with an optimal balance of safety, comfort, and performance.

One of the main features of the 3M G5 XT-1 is its advanced filtration technology. Equipped with highly efficient particulate filters, these respirators are designed to capture airborne particles, including dust, smoke, and other harmful contaminants. This effectiveness is further enhanced by the use of activated carbon in certain filter models, which provides an additional layer of protection against gases and odors. The filters are easy to replace, ensuring that users can maintain their equipment without hassle.

Another key characteristic of the G5 XT-1 is its ergonomic design. The respirator is engineered to provide an excellent fit, reducing the likelihood of leakage and ensuring that users receive optimal protection. The adjustable straps and customizable nose bridge allow for a snug fit on various face shapes and sizes, enhancing comfort during prolonged use. This is particularly important for professionals in fields such as construction, healthcare, and manufacturing, who may wear respirators for extended periods.

The G5 XT-1 also features a lightweight construction, which contributes to user comfort. This lightweight design, combined with features such as breathing valves, enhances airflow, reducing breathing resistance. This means that users can perform their tasks more efficiently while experiencing less fatigue.

Another notable technology integrated into the G5 XT-1 is its dual mode of operation. Users can switch between disposable and reusable options, which is particularly advantageous for those who want to balance cost and sustainability. The reusable aspect of the respirator also encourages environmental friendliness by reducing waste.

In conclusion, the 3M G5 XT-1 respirator is a comprehensive solution for those seeking high-performance respiratory protection. With its advanced filtration technologies, user-centric design, and flexible operation modes, the G5 XT-1 meets the diverse needs of professionals working in challenging environments. Its focus on safety, comfort, and adaptability secures its place as a top choice for respiratory protection in various industries.