3M G5, XT-1 Change Noise Reduction Level, List All Headsets, Resetting Inactive Days

Page 19

Configuration

Enter the base station configuration mode, see page 11.

Select 04 Registration > 2 Remove Headsets.

Scroll to the number of the headset you want to un-register.

Press Enter.

Note:

If you do not know or have access to the number of the headset to be un- registered, identify the headsets that you want to remain in service and un- register any that remain on the list.

List All Headsets

To see a list of the registered headsets:

Enter the base station configuration mode, see page 11.

Select 04 Registration > 3 List All Headsets.

Resetting Inactive Days

For any headset, you can manually reset its number of inactive days to zero (see “Change Self Monitoring” on page 27 for information about the inactive days timer.

To reset the inactive days:

Enter the base station configuration mode, see page 11.

Navigate to 08 Headset Setup > Currently Editing Headset.

Press or if necessary to scroll to the headset ID number for the headset you want to reset.

Select <CLEAR>.

Checking Headset Software Revision

To check the software revision number for a headset:

Enter the base station configuration mode, see page 11.

Navigate to 08 Headset Setup > Currently Editing Headset.

Press or if necessary to scroll through the headsets. The software version appears below the headset ID number.

Change Noise Reduction Level

There are several ways to improve the sound quality at the headset using the following settings.

Inbound Microphone Noise Reduction Level

The inbound microphone noise reduction level setting reduces background noise to make it easier to hear speech at the customer order point.

Perform the following steps to increase or decrease the noise reduction level.

Enter the base station configuration mode, see page 11.

Make a new selection for 05 Noise Reduction > Inbound Mic Noise Reduction Level. Options are Off, Min, Low, Med, Hi, and

Max. You may need to experiment for a setting that works best for your ambient noise environment.

3M™ Drive-Thru Systems Model G5 and Model XT-1

November 6 2014 – Revision 2.1

Operating Instructions

Page 19 of 77

Image 19
Contents Operating Instructions 3M Commercial Solutions Division Table of Contents Assembling a 3M Drive Thru Headset G5 Maintenance Index Alert Message External Trigger InputsOverview Safety InformationFCC and Industry Canada Information Other ConventionsImportant Notes and Notes Important NoteFCC and IC Identifiers FCC NoteRecycling / Disposal Notice to European Union customers Enter Configuration Mode ConfigurationNavigating the Base Station Display Buttons Interpreting Display InformationConfiguring with a Computer Logging into the Base Station with a PC ∙ Cycle the power to the base stationVehicle Alert Volume Change Basic Volume SettingsInbound Microphone Volume Outbound Talk VolumeVehicle Present Change the Monitor VolumeInbound Listen Outbound TalkGreeter Messages Change the Night VolumeVehicle Approach MessagesAdd Headsets Registering HeadsetsRemove Headsets Checking Headset Software Revision List All HeadsetsResetting Inactive Days Change Noise Reduction LevelSet System Date and Time Change Global SettingsAcoustic Echo Canceller Drive Thru Audio Duplex ModeNumber of Base Stations at this Site Channel Heard by Order TakerStore is Now Closed Prompt Customer Order Point Prompt Language Pull Ahead PromptOrder Point Talk with No Vehicle Order Takers and Page Messages in Cross Lane ModeDetector Type Important Notes Kitchen Noise ReductionBlue LED Alerts on Headsets Order Taking Modes SetupXT-1 Basestation Software Update Kit XT-1 Haptics Vibration Alerts on HeadsetsRegular Site Schedule Change Site SchedulingHoliday/Exception Schedule User Passcodes Change Site InformationChange Self Monitoring Change PasscodesSave Installation Settings Two Base Station SetupInstaller Setup Load Installation SettingsCreate and Load Templates Factory Setup Restore Factory DefaultsReboot System Activate the Backup IntercomPage 3M Drive Thru Headset G5 OperationNovember 6 2014 Revision Operation 3M Drive-Thru Systems Model G5 and Model XT-1 ∙ T1 and T2 Talkbuttons Connect you to the order point Component Identification and DescriptionG5 Battery Indicator Light Modes Indicator Light ModesG5 Headset Indicator Light Modes Fitting the Headset Replace the Battery Cleaning XT-1 HeadsetsOut of Range Component Identification and Description Headset Replace the Battery Out of Range Navigating in the Base Station in Run Mode Base Station SetupChange Order Taking Mode Listen Auto, Manual, and Always On Explanation of Order Taking ModesTalk Manual Latching, Push to Talk, Automatic Change Lane Mode Which Order Taking Mode to SelectSplit Lane Cross Lane Change Volume ModeDisassembling the Carrier from the Pod MaintenanceG5 Headset Replacing the CarrierLocation G5 Headset ChargerRefitting the headset with the new Carrier Replacing the Ear and Headband PadsCare, Handling and Storage Cleaning the Contacts in the Headset Charger wellsLow Battery Message G5 BatteriesMaking Sure Batteries are Ready for Use Disposing of BatteriesImportant Information about Rechargeable Batteries XT-1 Batteries XT-1 Battery ChargerCleaning the Contacts XT-1 HeadsetCharging Status Indicator Important Information about Rechargeable Batteries Headset Indicator Lights TroubleshootingG5 Headset Indicator Light Modes Problem Possible Cause Solution General TroubleshootingPress the other button into the correct XT-1 Battery and Battery Charger Battery and Battery Charger TroubleshootingAppendix Declaration of Conformity Functional Appendix Base Station SpecificationsPhysical ElectricalAppendix G5 Charger Specifications Enter the Greeter Configuration Menu Greeter SetupAppendix Greeter Module Record Message Message ActivationChoose Headsets Messages Playback To NameBreakfast Service=StartMessage Daypart Definitions Change Playback Delay TimeGreeter Message Properties Set Playback through Monitor Change Playback ModeSet Greeter Playback through Headsets Turn on Tone to Headsets During Greeter PlaybackTurn on External Detector Playback Message Turn on Restaurant Closed Playback MessageGreeter Revision Alert & Reminder Message Properties Alert & Reminder Message PropertiesDual Lane Systems Lane Message NamesTandem Pull Ahead Playback Message Delay Count Greeter Setup System DefaultsStart Time Alert & Reminder Properties Greeter Setup Customer SettingsGreeter Setup Example Settings 66, 67, 68, 69 IndexTalk 3M, Thinsulate, Tufcote and ScotchBrite are trademarks of 3M
Related manuals
Manual 8 pages 46.54 Kb

G5, XT-1 specifications

The 3M G5 XT-1 is a cutting-edge respirator designed for professionals who require advanced protection in various hazardous environments. With its innovative features, this respirator stands out in the market, providing users with an optimal balance of safety, comfort, and performance.

One of the main features of the 3M G5 XT-1 is its advanced filtration technology. Equipped with highly efficient particulate filters, these respirators are designed to capture airborne particles, including dust, smoke, and other harmful contaminants. This effectiveness is further enhanced by the use of activated carbon in certain filter models, which provides an additional layer of protection against gases and odors. The filters are easy to replace, ensuring that users can maintain their equipment without hassle.

Another key characteristic of the G5 XT-1 is its ergonomic design. The respirator is engineered to provide an excellent fit, reducing the likelihood of leakage and ensuring that users receive optimal protection. The adjustable straps and customizable nose bridge allow for a snug fit on various face shapes and sizes, enhancing comfort during prolonged use. This is particularly important for professionals in fields such as construction, healthcare, and manufacturing, who may wear respirators for extended periods.

The G5 XT-1 also features a lightweight construction, which contributes to user comfort. This lightweight design, combined with features such as breathing valves, enhances airflow, reducing breathing resistance. This means that users can perform their tasks more efficiently while experiencing less fatigue.

Another notable technology integrated into the G5 XT-1 is its dual mode of operation. Users can switch between disposable and reusable options, which is particularly advantageous for those who want to balance cost and sustainability. The reusable aspect of the respirator also encourages environmental friendliness by reducing waste.

In conclusion, the 3M G5 XT-1 respirator is a comprehensive solution for those seeking high-performance respiratory protection. With its advanced filtration technologies, user-centric design, and flexible operation modes, the G5 XT-1 meets the diverse needs of professionals working in challenging environments. Its focus on safety, comfort, and adaptability secures its place as a top choice for respiratory protection in various industries.