Chapter 4

Chapter 4 Command Set
4-11

ADAM-4015/ADAM-4015T Command Table

Command
Syntax Comm an d Na m e
Command Description
Page
No.
%AANNTTCCFF
Configuration
Sets the address, baud rate, data format,
chec k s u m s tatus, an d/ o r integr a t ion ti m e f or a
specified analog input module
5-4
$AA2 Configuration Status Returns the configuration parameters for the
specified analog input module 5-10
$AAF Read Firmware
Version Return the firmware version code from the
specified analog input module 5-12
$AAM Read Module Name Return the module name from the specifie d
analog input module 5-13
#AA
A
nalog Data In
Retur n s th e i n put value f r om a sp ec if ied an al o g
input module in the currently configured data
format
5-14
#AAN Read Analog Input
from Channel N Retur n s th e i n put val u e f r om a s pecifie d c h an n el
of analog input module in the currently configured
data format
5-16
$AA5VV Enable/Disable
Channels for
Multiplexing
Enable or disable the individual channels in an
analog module 5-17
$AA6 Read Channel
Status Get t he enable/disable status of all channels in
an analog module 5-18
#** Synchronized
Sampling Orders all analog input modules t o sample their
input values and store them in special registers 5-21
$AA4 Read Synchronized
Data Ret ur ns t h e v alue t h at wa s s tored in t he s pecif i e d
modu l e' s regis t e r after t he #** c om m an d 5-22
$AAB Channel Diagnose
Diagnose channel status in over range, under
range, and wire opening 5-24
$AA0Ci Single Channel
Span Calibration Calibrates a s p ec ifie d c h annel t o c or r e c t for ga i n
errors 5-27
$AA1Ci Single Channel
Offset Calibration Calibrates a s p ec ifie d c h annel t o c or r e ct for offset
errors 5-28
$AA7CiRrr Single Channel
Range Configuration
Configure th e input type and range o f the
specified channel in an analog input mo dule 5-29
$AA8Ci Read Single
Channel Range
Configuration
Get th e in p ut type an d r an g e of t h e s p ec if i e d
channel in an analog input module 5-30
$AAXnnnn Watchdog Timer
Setting Set communication WDT cycle time from 0000 ~
9999 (unit: 0.1 second. if value is 0000, the
communication WDT f unction will be disable)
5-31
$AAY Read Watchdog
Timer Setting Read the cycle time setting of communication
WDT 5-32
$AAS0 Internal Calibration
Internal sel
f
-calibration for offset and
gai n er ror s 5-33
$AAS1 Reload default
calibrating
parameter
Reload factory default calibrating parameter to
over w r ite cur r ent cali brati n g p arame t e r 5-34