AEG PV.630 manual Auxiliary power supply via external circuit

Models: PV.630

1 128
Download 128 pages 35.18 Kb
Page 95
Image 95

Protect PV.630 Installation and Start-up

After connecting the AC voltage:

Auxiliary power supply via internally generated circuit 1

Switch on Q1 (external).

Switch on Q26 (external).

Measure the clockwise rotating field at X3 (AC control cabinet).

Measure the voltage at F61 (DC/AC control cabinet).

Switch on F61

The control unit and the DOU are now working.

Q4.1 (DC/AC control cabinet) switches on automatically after a few seconds.

Auxiliary power supply via external circuit 2

Switch on Q1 (external).

Switch on Q26 (external).

Measure the clockwise rotating field at X3 (AC control cabinet).

Connect the external power supply/auxiliary voltage at E1.

Measure the external voltage at E1.

Switch on F60 (DC/AC control cabinet)

The control unit and the DOU are now working.

Q4.1 (DC/AC control cabinet) switches on automatically after a few seconds.

80000047963 BAL