General Information
Trigger System
*Denotes Warranted Specifications, all others are typical. Specifications are valid after a
Trigger System
Sources: | 54621A/22A: Ch 1, 2, line, ext |
| 54621D/22D: Ch 1, 2, line, ext, D15 - D0 |
| 54624A: Ch 1, 2, 3, 4, line, ext |
Modes | Auto, Auto level, Triggered (normal), Single |
Holdoff Time | ~60 ns to 10 seconds |
Selections | Edge, Pattern, Pulse Width, CAN, Duration, I2C, Sequence, SPI, TV, USB |
Edge | Trigger on a rising or falling edge of any source. |
Pattern | Trigger on a pattern of high, low, and don’t care levels and a rising or falling edge |
| established across any of the sources. The analog channel’s high or low level is defined |
| by that channel’s trigger level. |
Pulse Width | Trigger when a positive- or |
| specified range on any of the source channels. |
| Minimum pulse width setting: 5 ns |
| Maximum pulse width setting: 10 s |
CAN | Trigger on CAN (Controller Area Network) version 2.0A and 2.0B signals. It can trigger |
| on the Start of Frame bit of a data frame, a remote transfer request frame, or an overload |
| frame. |
Duration | Trigger on a |
| than a value, greater than a time value with a timeout value, or inside or outside of a set |
| of time values. |
| Minimum duration setting: 5 ns |
| Maximum duration setting: 10 s |
I2C | Trigger on I2C |
| acknowledge, or user defined frame with address and/or data values. Also trigger on |
| Missing Acknowledge, Restart, EEPROM read, and |
LIN | Trigger on LIN (Local Interconnect Network) sync break at beginning of message frame. |
Sequence | Find event A, trigger on event B, with option to reset on event C or time delay. |
SPI | Trigger on SPI (Serial Peripheral Interface) a data pattern during a specific framing |
| period. Support positive and negative Chip Select framing ad well as clock Idle framing |
| and |
USB | Trigger on USB (Universal Serial Bus) Start of Packet, End of Packet, Reset Complete, |
| Enter Suspend, or Exit Suspend on the differential USB data lines. USB low speed and |
| high speed are supported. |
TV | Trigger on any analog channel for NTSC, PAL, |
| on either positive or negative composite video signals. Modes supported include Field |
| 1, Field 2, or both, all lines, or any line within a field. Also supports triggering on non- |
| interlaced fields. TV trigger sensitivity: 0.5 division of synch signal. |
Autoscale | Finds and displays all active analog and digital (for 54621D/54622D) channels, sets edge |
| trigger mode on highest numbered channel, sets vertical sensitivity on analog channels |
| and thresholds on digital channels, time base to display ~1.8 periods. Requires minimum |
| voltage >10 mVpp, 0.5% duty cycle and minimum frequency >50 Hz. |