Agilent Technologies 54622D The Oscilloscope At a Glance, Display shows current input signals

Models: 54621A 54622A 54622D 54621D 54624A

1 111
Download 111 pages 42.09 Kb
Page 2
Image 2
The Oscilloscope At a Glance

The Oscilloscope At a Glance

Choose from a variety of oscilloscopes for capturing long, non-repeating signals

with 200 MSa/s sample rate and 2 MBytes of MegaZoom deep memory per channel.

Agilent 54621A - 2-channel, 60-MHz bandwidth

Agilent 54621D - 2-channel +16 logic channels, 60- MHz bandwidth

Agilent 54622A - 2-channel, 100-MHz bandwidth

Agilent 54622D - 2-channel +16 logic channels, 100-MHz bandwidth

Agilent 54624A - 4-channel, 100-MHz bandwidth

Display shows current input signals

All analog and digital (54621D/22D) channels displayed in main and delayed mode

Indicators for channel, time base, digital (54621D/ 22D) channel activity, trigger and acquisition status

Softkey labels

Measurement results

Digital channel controls select, position, and label inputs (54621D/22D)

Turn channels on or off individually or in groups of 8

Rearrange order of channels to group related signals

Create and display labels to identify channels

Run control keys begin and end data acquisition

Run/Stop starts and stops continuous acquisitions

Single performs one acquisition

Infinite persistence accumulates and displays the results of multiple acquisitions

Horizontal Controls select sweep speed and delay parameters

Sweep speeds from 5 ns/div to 50 ns/div

Delay control moves waveform display to point of interest

Delayed mode and delay allow zooming in to show a portion of waveform in detail (split screen)

Trigger keys define what data the oscilloscope will trigger on

Source key allows conventional oscilloscope triggering

Modes include Edge, Pulse Width, Pattern, CAN, Duration, I2C, LIN, Sequence, SPI, TV, and USB triggering

General controls measure, save and restore results, and configure the oscilloscope

Waveform math including FFT, subtract, multiply, integrate, and differentiate

Use Quick Meas to make automatic measurements Integrated counter included with Quick Meas.

Use cursors to make manual measurements

Save or recall measurement configurations or previous results

Autoscale performs simple one-button setup of the oscilloscope

Softkeys extend the functionality of command keys

Select measurement types, operating modes, trigger specifications, label data, and more

Digital channel inputs through a flexible probing system (54621D/22D)

Sixteen channels through a dual 8-channel cable with micro-clips

Set logic levels as TTL, CMOS, ECL, or to a user- definable voltage

Utilities

Dedicated parallel printer port, controller operation, floppy disk storage

Built in Quick Help system

Press and hold any key front-panel key or softkey to get help in 11 languages.