Programming Reference

SCPI Instrument Command List

Command

:MMEM:INIT

Long

:MMEMory:INITialize

Form

Event

Parameter

["A:"[,"DOS"]]

*RST value

Not applicable

Description

Use this command to initialize a memory card to DOS format.

 

 

CAUTION

Initializing a memory card destroys any existing data on the card.

 

 

Command

:MMEM:LOAD:STAT

Long

:MMEMory:LOAD:STATe

Form

Event

Parameter

<n>,"filename"[,"A:"]

*RST value

Not applicable

Specified Limits

<n> = 0 to 4 (integer)

Description

Use this command to load a complete instrument setting from file

 

filename in the current directory into memory <n> in the instrument.

 

Memories 1 to 4 are the internal memories. Use memory 0 to load a

 

setting as the current instrument setting.

Examples

See next command

Command

:MMEM:STOR:STAT

Long

:MMEMory:STORe:STATe

Form

Event

Parameter

<n>,"filename"[,"A:"]

*RST value

Not applicable

58

Page 58
Image 58