Agilent Technologies E1439 manual Age1439datasetup, Blocksize

Models: E1439

1 246
Download 246 pages 11.5 Kb
Page 100
Image 100

Note

id

blocksize

Agilent E1439 Programmer's Reference

Functions listed alphabetically

age1439_data_setup

Sets all format and data output flow parameters. This description also includes information on the following functions which set or query the format and flow parameters individually:

age1439_data_blocksize determines the size of the output data block. age1439_data_blocksize_get gets the output data block size. age1439_data_delay determines the FIFO delay in continuous mode. age1439_data_delay_get gets the FIFO delay in continuous mode. age1439_data_mode selects block mode or continuous mode. age1439_data_mode_get gets the data mode. age1439_data_port selects VME bus or local bus output port. age1439_data_port_get gets the output port designation. age1439_data_resolution selects 12 or 24 bits data resolution. age1439_data_resolution_get gets the data resolution.

age1439_data_spectral_order specifies the spectral order of the output data. age1439_data_spectral_order_get gets the spectral order of the output data. age1439_data_type selects real or complex output data. age1439_data_type_get gets output data type.

VXIplug&play Syntax

#include "age1439".h

ViStatus age1439_data_setup(ViSession id, ViInt16 dataType, ViInt16 resolution, ViInt16 mode, ViInt32 blocksize, ViInt32 dataDelay, ViInt16 spectralOrder, ViInt16 port);

ViStatus age1439_data_blocksize(ViSession id, ViInt32 blocksize); ViStatus age1439_data_blocksize_get(ViSession id, ViPint32 blocksizePtr); ViStatus age1439_data_delay(ViSession id, ViInt32 dataDelay); ViStatus age1439_data_delay_get(ViSession id, ViPInt32 dataDelayPtr); ViStatus age1439_data_mode(ViSession id, ViInt16 mode);

ViStatus age1439_data_mode_get(ViSession id, ViPInt16 modePtr); ViStatus age1439_data_port(ViSession id, ViInt16 port); ViStatus age1439_data_port_get(ViSession id, ViPInt16 portPtr); ViStatus age1439_data_resolution(ViSession id, ViInt16 resolution);

ViStatus age1439_data_resolution_get(ViSession id, ViPInt16 resolutionPtr); ViStatus age1439_data_spectral_order(ViSession id, ViInt16 spectralOrder); ViStatus age1439_data_spectral_order_get(ViSession id, ViPInt16 spectralOrderPtr); ViStatus age1439_data_type(ViSession id, ViInt16 dataType);

ViStatus age1439_data_type_get(ViSession id, ViPInt16 dataTypePtr);

Description

The functions, age1439_data_delay, age1439_data_mode, age1439_data_resolution, and age1439_data_type work the same for the fiber interface as they do for the other interfaces.

Parameters

is the VXI instrument session pointer returned by the age1439_init function. determines the number of sample points in each output data block. AGE1439_BLOCKSIZE_MIN selects the minimum blocksize.

90